3. COMMAND2 (Vertical display start position and vertical character size setting command)
First byte
Second byte
Note: The register states are all set to zero when the LC74723 is reset with the RST pin.
4. COMMAND3 (Horizontal display start position and horizontal character size setting command)
First byte
No. 4841-8/12
LC74723, 74723M
DA
Register
Contents
Remarks
0 to 7
name
State
Function
7—
1
6—
0
Command 2 identification code
5—
1
Set vertical display start position and vertical character size.
4—
0
3—
0
2
VS20
0
1H per dot
Second line vertical character size
1
2H per dot
1—
0
VS10
0
1H per dot
First line vertical character size
1
2H per dot
DA
Register
Contents
Remarks
0 to 7
name
State
Function
7—
0
Second byte identification code
6FS
0
Crystal oscillator frequency: 2fsc
1
Crystal oscillator frequency: 4fsc
5
VP5
0
(MSB)
1
4
VP4
0
1
3
VP3
0
1
2
VP2
0
1
VP1
0
1
0
VP0
0
(LSB)
1
DA
Register
Contents
Remarks
0 to 7
name
State
Function
7—
1
6—
0
Command 3 identification code
5—
1
Set horizontal display start position and horizontal character size.
4—
1
3
EGP
0
Correction: on
Trimming specifications when the horizontal
1
Correction: off
character size is doubled
2
HS20
0
1Tc per dot
Second line horizontal character size
1
2Tc per dot
1—
0
HS10
0
1Tc per dot
First line horizontal character size
1
2Tc per dot
The vertical display start position is set by the
6 bits VP0 to VP5.
The weight of the low-order bit is 2H.
If VS is the vertical display start position then:
H: the horizontal synchronization pulse period
VS = H × (2Σ 2n VPn)
n = 0
5