Cassette Style
AC-DC Converters
K Series
Edition 5/5.2000
18/26
Table 13: Isolation
Characteristic
Input to
Output to Output to
Unit
case
output
case
output
Electric
Required according to
1.5
3.0 1
––
kVrms
strength
IEC/EN 60950
2.1
4.2 1
––
kV DC
test voltage
Actual factory test 1 s
2.8
5.6 1
1.4
0.14
AC test voltage equivalent
2.0
4.0 1
1.0
0.1
kVrms
to actual factory test
Insulation resistance at 500 V DC
>300
>100 2
M
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
2 Tested at 100 V DC.
For creepage distances and clearances refer to:
Technical Information: Safety.
Installation Instructions
The K series AC-DC converters are components, intended
exclusively for inclusion within other equipment by an in-
dustrial assembly operation or by professional installers. In-
stallation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation require-
ments of the end-use application.
Connection to the system shall be made via the female con-
nector H15/H15 S4 (see:
Accessories). Other installation
methods may not meet the safety requirements.
The AC-DC converters are provided with pin no. 24 ( ),
which is reliably connected with their case. For safety rea-
sons it is essential to connect this pin with the protective
earth of the supply system.
An input fuse is built-in in the connection from pins no. 30
and 32 (P ) of the unit. Since this fuse is designed to pro-
tect the unit in case of an overcurrent and does not neces-
sarily cover all customer needs, an external fuse suitable
for the application and in compliance with the local require-
ments might be necessary in the wiring to one or both input
potentials, pins nos. 26 and 28 and/or nos. 30 and 32.
Important: Whenever the inhibit function is not in use, pin
no. 18 (i) should be connected to pin no. 14 (S–/Vo1–) to
enable the output(s).
Do not open the modules, or guarantee will be invalidated.
Due to high current values, all LK units provide two inter-
nally parallel connected contacts for certain paths (pins 4/6,
8/10, 26/28 and 30/32, respectively). It is recommended to
connect load and supply to both female connector pins of
each path in order to keep the voltage drop across the con-
nector pins to an absolute minimum and to not overstress
the connector contacts if currents are higher than
approx. 8 A. The connector contacts are rated 8 A over the
whole temperature range.
Make sure that there is sufficient air flow available for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature
TC max shall not be exceeded. See also: Thermal
Considerations.
If the end-product is to be UL certified, the temperature of
the main isolation transformer should be evaluated as part
of the end-product investigation.
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also:
Safety
of operator accessible output circuit.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Important: Testing by applying AC voltages will result in
high and dangerous leakage currents flowing through
the Y-capacitors (see fig.:
Block diagram).
Protection Degree
Condition: Female connector fitted to the unit.
IP 30: All units except those with option P, and except
those with option D or V with potentiometer.
IP 20: All units fitted with option P, or with option D or V with
potentiometer.
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
相关PDF资料
PDF描述
LK1001-9PDDB1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1001-9RV0TB2 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1301-7ED8B1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1301-7EPD2TB1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1301-7EPD6TB1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
LK100-24P 制造商:未知厂家 制造商全称:未知厂家 功能描述:Optoelectronic
LK100-28P 制造商:未知厂家 制造商全称:未知厂家 功能描述:Optoelectronic
LK10051R0K-T 功能描述:固定电感器 INDCTR STD MULTILYR 0402 1uH 10% RoHS:否 制造商:AVX 电感:10 uH 容差:20 % 最大直流电流:1 A 最大直流电阻:0.075 Ohms 工作温度范围:- 40 C to + 85 C 自谐振频率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接类型:SMD/SMT 封装 / 箱体:6.6 mm x 4.45 mm
LK10051R0K-T 制造商:TAIYO YUDEN 功能描述:Inductor Series:LF LK
LK10051R0K-TV 功能描述:FIXED IND 1UH 20MA 640 MOHM SMD 制造商:taiyo yuden 系列:LK 包装:剪切带(CT) 零件状态:在售 类型:多层 材料 - 磁芯:- 电感:1μH 容差:±10% 额定电流:20mA 屏蔽:无屏蔽 DC 电阻(DCR):640 毫欧 不同频率时的 Q 值:20 @ 10MHz 频率 - 自谐振:60MHz 等级:AEC-Q200 工作温度:-40°C ~ 85°C 频率 - 测试:10MHz 安装类型:表面贴装 封装/外壳:0402(1005 公制) 供应商器件封装:0402(1005 公制) 大小/尺寸:0.039" 长 x 0.020" 宽(1.00mm x 0.50mm) 高度 - 安装(最大值):0.022"(0.55mm) 标准包装:1