Table 13: Isolation
Characteristic
Input to
Output to Output to
Unit
case
output
case
output
Electric
Required according to
1.5
3.0 1
––
kVrms
strength
IEC/EN 60950
2.1
4.2 1
––
kV DC
test voltage
Actual factory test 1 s
2.8
5.6 1
1.4
0.14
AC test voltage equivalent
2.0
4.0 1
1.0
0.1
kVrms
to actual factory test
Insulation resistance at 500 V DC
>300
>100 2
M
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
2 Tested at 100 V DC.
For creepage distances and clearances refer to:
Technical Information: Safety.
Due to high current values, all LK units provide two inter-
nally parallel connected contacts for certain paths (pins 4/6,
8/10, 26/28 and 30/32, respectively). It is recommended to
connect load and supply to both female connector pins of
each path in order to keep the voltage drop across the con-
nector pins to an absolute minimum and to not over-
stress the connector contacts if currents are higher than
approx. 8 A. The connector contacts are rated 8 A over the
whole temperature range.
Make sure that there is sufficient air flow available for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature
TC max shall not be exceeded. See also: Thermal
Considerations.
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also:
Safety
of operator accessible output circuit.
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
Protection Degree
Condition: Female connector fitted to the unit.
IP 30: All units except those with option P, and except
those with option D or V with potentiometer.
IP 20: All units fitted with option P, or with option D or V
with potentiometer.
Standards and Approvals
All AC-DC converters correspond to class I equipment.
They are UL recognized according to UL 1950, UL recog-
nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA
approved to IEC/EN 60950 standards.
The units have been evaluated for:
Building in
Basic insulation between input and case, based on 250 V
AC and 400 V DC
Double or reinforced insulation between input and output,
based on 250 V AC and 400 V DC
Basic insulation between output and case based on
200 V AC and DC.
Operational insulation between output and output
The use in a pollution degree 2 environment
Connecting the input to a primary or secondary circuit
which is subject to a maximum transient rating of 2500 V
(overvoltage category III based on a 110 V primary cir-
cuit, overvoltage category II based on a 230 V primary
circuit).
The UL 1950 recognition limits the maximum case tem-
perature of the standard modules to
TC = TC max – 10 K =
95
°C.
The AC-DC converters are subject to manufacturing sur-
veillance in accordance with the above mentioned UL,
CSA, EN and with ISO 9001 standards.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Important: Testing by applying AC voltages will result in
high and dangerous leakage currents flowing through
the Y-capacitors (see fig.:
Block diagram).
相关PDF资料
PDF描述
LK4003-9RD1TB2 1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE
LK4003-9RD6T 1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE
LK4301-9EPD1B2 1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE
LK4501-9EPD0B1 1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE
LK4501-9EPD3B2 1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE
相关代理商/技术参数
参数描述
LK4010410 制造商: 功能描述: 制造商:undefined 功能描述:
LK402-25 功能描述:LCD字符显示模块与配件 Yel/Grn Background Black Text RoHS:否 制造商:Lumex 显示模式:Transflective 字符计数 x 行:16 x 2 特点: 流体类型:STN 接口: 背景色: 工作温度范围:- 20 C to + 70 C 封装:Bulk
LK402-25-422 功能描述:LCD字符显示模块与配件 40x2 Blk Txt Y/G B/G 25 key LCD RoHS:否 制造商:Lumex 显示模式:Transflective 字符计数 x 行:16 x 2 特点: 流体类型:STN 接口: 背景色: 工作温度范围:- 20 C to + 70 C 封装:Bulk
LK402-25-422-E 功能描述:LCD字符显示模块与配件 40x2 Blk Txt Y/G B/G Ext. Temp 25 key RoHS:否 制造商:Lumex 显示模式:Transflective 字符计数 x 行:16 x 2 特点: 流体类型:STN 接口: 背景色: 工作温度范围:- 20 C to + 70 C 封装:Bulk
LK402-25-422-V 功能描述:LCD字符显示模块与配件 40x2 Blk Txt Y/G B/G Ext.Volt 25 key RoHS:否 制造商:Lumex 显示模式:Transflective 字符计数 x 行:16 x 2 特点: 流体类型:STN 接口: 背景色: 工作温度范围:- 20 C to + 70 C 封装:Bulk