Digital Temperature Sensor and Thermal
Watchdog with 2-Wire Interface
_______________________________________________________________________________________   3
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
LOGIC (SDA, SCL, A0, A1, A2)
Input High Voltage
V
IH
+V
S
x
0.7
+V
S
+
0.5
V
Input Low Voltage
V
IL
-0.3
+V
S
x
0.3
V
Input High Current
I
IH
V
IN
= 5V
0.005
1.0
礎
Input Low Current
I
IL
V
IN
= 0V
-1.0
-0.005
礎
Input Capacitance
C
IN
All digital inputs
20
pF
Output High Current
V
OH
= 5V
10
礎
Output Low Voltage
I
OL
= 3mA
0.4
V
I
2
C-COMPATIBLE TIMING (Notes 12, 13)
(Clock) SCL Period
t
SCL
Bus timeout inactive
2.5
祍
Data In Setup Time to SCL High
t
SU:DAT
10% of SDA to 10% of SCL
100
ns
Data Out Stable After SCL Low
t
HD:DAT
10% of SCL to 10% of SDA
0
祍
Start Condition Setup Time
(SDA Low to SCL Low)
t
SU:STA
90% of SCL to 90% of SDA
100
ns
STOP Condition Hold Time
t
HD:STO
100
ns
SDA Time Low for Reset of Serial
Interface
t
TIMEOUT
(Note 14)
75
325
ms
ELECTRICAL CHARACTERISTICS (continued)
(+V
S
= +3.0V to +5.5V, unless otherwise noted. Temperature accuracy specifications apply for +V
S
= 3.3V for versions with -3 in
the suffix and for +V
S
= 5V for versions with -5 in the suffix. T
A
= -55癈 to +125癈, unless otherwise noted. Typical values are at
+V
S
= +5V, T
A
= +25癈.) (Notes 4, 5)
Note 4:    All parts operate properly over the 3V to 5.5V supply voltage range. The devices are tested and specified for rated
accuracy at their nominal supply voltage.
Note 5:    All parameters are measured at T
A
= +25癈. Values over the temperature range are guaranteed by design.
Note 6:    There is no industry-wide standard for temperature accuracy specifications. Maxims standard is six-sigma. The three-
sigma specification is included to allow easier comparison to products built by manufacturers who use different standards.
Note 7:    This specification indicates how often temperature data is updated. The devices can be read at any time without regard to
conversion state, while yielding the last conversion result.
Note 8:    For best accuracy, minimize output loading. Higher sink currents can affect sensor accuracy due to internal heating.
Note 9:    OS delay is user programmable up to 6 over-limit conversions before OS is set to minimize false tripping in noisy environ-
ments.
Note 10:  Guaranteed by design.
Note 11:  Default values set at power-up.
Note 12:  All timing specifications are guaranteed by design.
Note 13:  Unless otherwise noted, these specifications apply for +V
S
= +5VDC for LM75BIM-5 and LM75BIMM-5 and +V
S
=
+3.3VDC for LM75BIM-3 and LM75BIMM-3. C
L
(load capacitance) on output lines = 80pF, unless otherwise specified.
The switching characteristics of the LM75 fully meet or exceed the published specifications of the I
2
C bus. These parame-
ters are the timing relationships between SCL and SDA signals related to the LM75. They are not I
2
C bus specifications.
Note 14:  Holding the SDA line low for a time greater than t
TIMEOUT
causes the device to reset SDA to the IDLE state of the
serial bus communication (SDA set high).