参数资料
型号: LM89-1CIMM/NOPB
厂商: National Semiconductor
文件页数: 11/32页
文件大小: 0K
描述: IC TEMP SENSOR DGTL 8-MSOP
标准包装: 1,000
功能: 温度监控系统(传感器)
传感器类型: 内部和外部
感应温度: 0°C ~ 125°C
精确度: ±3°C(最小值)
拓扑: ADC(三角积分型),比较器,寄存器库
输出类型: 2 线 SMBus?
输出警报:
输出风扇:
电源电压: 3 V ~ 3.6 V
工作温度: 0°C ~ 125°C
安装类型: 表面贴装
封装/外壳: 8-TSSOP,8-MSOP(0.118",3.00mm 宽)
供应商设备封装: 8-MSOP
包装: 带卷 (TR)
配用: LM89-1EVAL-ND - BOARD EVALUATION LM89-1
其它名称: LM89-1CIMM
LM89-1CIMM-ND
LM89-1CIMM/NOPBTR
SNIS128C – AUGUST 2002 – REVISED MARCH 2013
5. Master/slave NoACK
6. Master sends STOP
7. Master attends to conditions that caused the ALERT to be triggered. The STATUS REGISTER is read and
fan started, setpoint limits adjusted, etc.
8. Master resets the ALERT mask (D7 in the Configuration register).
The ARA, 000 1100, is a general call address. No device should ever be assigned this address.
Bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (xBF) must be set low in
order for the LM89 to respond to the ARA command.
The ALERT output can be disabled by setting the ALER T mask bit, D7, of the Configuration register. The power-
on-default is to have the ALERT mask bit and the ALERT configure bit low.
Remote High Limit
RDTS Measurement
LM89 ALERT pin
ALERT mask set in
response to ARA
from master
Status Register: RTDS High
TIME
Figure 6. ALERT Output as an SMBus ALERT Temperature Response Diagram
T_CRIT_A OUTPUT and T_CRIT LIMIT
T_CRIT_A is activated when any temperature reading is greater than the limit preset in the critical temperature
setpoint register (T_CRIT), as shown in Figure 7 . The Status Register can be read to determine which event
caused the alarm. A bit in the Status Register is set high to indicate which temperature reading exceeded the
T_CRIT setpoint temperature and caused the alarm, see STATUS REGISTER (SR) .
Local and remote temperature diodes are sampled in sequence by the A/D converter. The T_CRIT_A output and
the Status Register flags are updated after every Local and Remote temperature conversion. T_CRT_A follows
the state of the comparison, it is reset when the temperature falls below the setpoint RCS-TH. The Status
Register flags are reset only after the Status Register is read and if a temperature conversion(s) is/are below the
T_CRIT setpoint, as shown in Figure 7 .
Figure 7. T_CRIT_A Temperature Response Diagram
Copyright ? 2002–2013, Texas Instruments Incorporated
Product Folder Links: LM89
11
相关PDF资料
PDF描述
RBC10DRAN CONN EDGECARD 20POS R/A .100 SLD
RCM08DCTT CONN EDGECARD 16POS DIP .156 SLD
2206-H-RC INDUCTOR TORD HI AMP 27UH HORZ
TPSC685K035R0350 CAP TANT 6.8UF 35V 10% 2312
TAP336K016BRW CAP TANT 33UF 16V 10% RADIAL
相关代理商/技术参数
参数描述
LM89-1CIMMX 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
LM89-1CIMMX/NOPB 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
LM89-1CIMX 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
LM89-1CIMX/NOPB 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
LM89-1DIMM/NOPB 功能描述:SENSOR TEMPERATURE SMBUS 8VSSOP 制造商:texas instruments 系列:- 包装:* 零件状态:有效 传感器类型:数字,本地 检测温度 - 本地:0°C ~ 85°C 检测温度 - 远程:0°C ~ 85°C 输出类型:SMBus 电压 - 电源:3 V ~ 3.6 V 分辨率:7 b(本地),10 b(远程) 特性:单触发,输出开关,可编程极限,关断模式,待机模式 精度 - 最高(最低):±3°C 测试条件:25°C ~ 125°C 工作温度:0°C ~ 125°C 封装/外壳:8-TSSOP,8-MSOP(0.118",3.00mm 宽) 供应商器件封装:8-VSSOP 标准包装:1