Cassette Style
100 Watt AC-DC (DC-DC) Converters
S Series
Edition 01/01.2001
8/25
Thermal Considerations
If a converter is located in free, quasi-stationary air (con-
vection cooling) at the indicated maximum ambient tem-
perature
TA max (see table: Temperature specifications) and
is operated at its nominal input voltage and output power,
the temperature measured at the
Measuring point of case
temperature TC (see: Mechanical Data) will approach the
indicated value
TC max after the warm-up phase. However,
the relationship between
TA and TC depends heavily on the
conditions of operation and integration into a system. The
thermal conditions are influenced by input voltage, output
current, airflow and temperature of surrounding compo-
nents and surfaces.
TA max is therefore, contrary to TC max,
an indicative value only.
Caution: The installer must ensure that under all operat-
ing conditions
TC remains within the limits stated in the
table:
Temperature specifications.
Notes: Sufficient forced cooling or an additional heat sink
allows
TA to be higher than 71
°C (e.g. 85°C) if T
C max is not
exceeded.
For -7 or -9 units at an ambient temperature
TA of 85
°C with
only convection cooling, the maximum permissible current
for each output is approx. 40% of its nominal value as per
figure.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
50
60
70
80
90
100
Io/Io nom
TA [°C]
0.9
1.0
Forced cooling
05089
TA min
TC max
Convection cooling
Output Voltage Regulation of Single or Double Output
Modules with Outputs 1 and 2 Connected in Series
Fig. 9
Uo1 vs. Io1 (typ.) of single output units
Uo
Uo nom
0.98
0.5
0
0.5
1.0
Io1
IoL
Io
Io nom
05068
Fig. 7
Output current derating versus temperature for -7 and -9
Thermal Protection
A temperature sensor generates an internal inhibit signal
which disables the outputs if the case temperature exceeds
TC max. The outputs are automatically re-enabled if the tem-
perature drops below this limit.
It is recommended that continuous operation under simul-
taneous extreme worst case conditions of the following
three parameters be avoided: Minimum input voltage,
maximum output power and maximum temperature.
Output Protection
Each output is protected against overvoltage which could
occur due to a failure of the control circuit by means of a
voltage suppressor diode which, under worst case condi-
tions, may become a short circuit. The suppressor diodes
are not designed to withstand externally applied over-
voltages. Overload at any of the two outputs will cause a
shut-down of both outputs. A red LED indicates the over-
load condition.
Parallel or Series Connection of Units
Single or double output units with equal nominal output
voltage can be connected in parallel without any precau-
tions using option T.
With option T (current sharing), all units share the current
approximately equally.
Single output units and/or main and second outputs of dou-
ble output units can be connected in series with any other
(similar) output.
Note:
– Parallel connection of double output units should always
include both, main and second output to maintain good
regulation of both outputs.
– Not more than 5 units should be connected in parallel.
– Series connection of second outputs without involving
their main outputs should be avoided as regulation may
be poor.
– The maximum output current is limited by the output with
the lowest current limitation if several outputs are con-
nected in series.
Uo1d
t d
Ur
t
Uo2d
<10
s
<10
s
Uo1
Uo2
Io1/Io1 nom
0
0.5
1
Io2/Io2 nom
05072
Fig. 8
Typical dynamic load regulation of Uo1 and Uo2
相关PDF资料
PDF描述
LS1601-7PDDTB2 1-OUTPUT 100 W AC-DC REG PWR SUPPLY MODULE
LS1601-9EPB2 1-OUTPUT 100 W AC-DC REG PWR SUPPLY MODULE
LS1601-9ERD7TB2 1-OUTPUT 100 W AC-DC REG PWR SUPPLY MODULE
LS1601-9RD2B2 1-OUTPUT 100 W AC-DC REG PWR SUPPLY MODULE
LS2320-7EPD3B2 2-OUTPUT 100 W AC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
LS1601-7R 功能描述:线性和开关式电源 Euro-Cassette 100W (24V) RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
LS1601-9ER 制造商:Power-One 功能描述:ACDC - Bulk
LS1601-9ERB1 制造商:Power-One 功能描述:AC-DC 100 WATT PFC CONVERTER -40 TO 71 C COOL PLATE STD CASE - Bulk
LS1601-9R 制造商:Power-One 功能描述:100W,AC,DC, 24V OUT, RUGGED - Bulk
LS1608 制造商:ICE 制造商全称:ice Components, Ins. 功能描述:Surface Mount Power Inductors