19/27
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the H15 con-
nector. Pin no. 24, the protective earth pin present on all LS
AC-DC converters is leading, ensuring that it makes con-
tact with the female connector first.
4
32
Type H15
10002
Table 12: H15 Connector pin allocation
Pin
Connector type H 15
No.
LS 4000
LS 5000
4
Vo1+
Output 1
Vo2+
Output 2
6
Vo1+
Vo2+
8Vo1–
Output 1
Vo2–
Output 2
10
Vo1–
Vo2–
12
S+
Sense
Vo1+
Output 1
14
S–
Sense
Vo1–
Output 1
16
R 1
Control of
U o1
R 1
Control of
U o1
18
i
Inhibit
i
Inhibit
20
D
Save data
D
Save data
V 3
ACFAIL
22
T
Current sharing
T
Current sharing
24 2
Protective earth
26
N
Neutral
N
Neutral
28
N
N
30
P
Phase
P
Phase
32
P
P
1 Feature R excludes option P and vice versa
2 Leading pin (pregrounding)
3 Option D excludes option V and vice versa
Installation Instructions
The S series AC-DC converters are components, intended
exclusively for inclusion within other equipment by an in-
dustrial assembly operation or by professional installers. In-
stallation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation require-
ments of the end-use application.
Connection to the system shall be made via the female con-
nector H15 (see:
Accessories). Other installation methods
may not meet the safety requirements.
The AC-DC converters are provided with pin no. 24 ( ),
which is reliably connected with their case. For safety rea-
sons it is essential to connect this pin with the protective
earth of the supply system.
An input fuse is built-in in the connection from pins no. 30
and 32 (P
) of the unit. Since this fuse is designed to pro-
tect the unit in case of an overcurrent and does not neces-
sarily cover all customer needs, an external fuse suitable
for the application and in compliance with the local require-
ments might be necessary in the wiring to one or both input
potentials, pins nos. 26 and 28 and/or nos. 30 and 32.
Important: Whenever the inhibit function is not in use,
pin no. 18 (i) should be connected to pin no. 14 (S–/Vo1–)
to enable the output(s).
Do not open the modules, or guarantee will be invali-
dated.
Due to high current values, all LS units provide two inter-
nally parallel connected contacts for certain paths (pins 4/6,
8/10, 26/28 and 30/32, respectively). It is recommended to
connect load and supply to both female connector pins of
each path in order to keep the voltage drop across the con-
nector pins to an absolute minimum and to not overstress
the connector contacts if currents are higher than
approx. 8 A. The connector contacts are rated 8 A over the
whole temperature range.
Make sure that there is sufficient air flow available for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature
TC max shall not be exceeded. See also: Thermal
Considerations.
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also:
Safety
of operator accessible output circuit.
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
Fig. 27
View of module’s male H15 connector
Protection Degree
Condition: Female connector fitted to the unit.
IP 30: All units except those with option P, and except
those with option D or V with potentiometer.
IP 20: All units fitted with option P, or with option D or V with
potentiometer.
相关PDF资料
PDF描述
LS4301-9RD0 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
LS4301-9RD2TB2 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
LS4501-7EPTB1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
LS4501-7ERD5B1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
LS4501-7PB1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
相关代理商/技术参数
参数描述
LS430850 功能描述:SCR MOD ISO SGL 800V 500A RoHS:是 类别:半导体模块 >> SCR 系列:- 其它有关文件:SCR Module Selection Guide 标准包装:10 系列:- 结构:串联 - SCR/二极管 SCR 数目,二极管:1 SCR,1 个二极管 电压 - 断路:1600V 电流 - 栅极触发电流 (Igt)(最大):150mA 电流 - 导通状态 (It (AV))(最大):95A 电流 - 导通状态 (It (RMS))(最大):210A 电流 - 非重复电涌,50、60Hz (Itsm):1785A,1870A 电流 - 维持(Ih):250mA 安装类型:底座安装 封装/外壳:ADD-A-PAK(3 + 2) 包装:散装 其它名称:*IRKL92/16AIRKL92/16IRKL92/16-ND
LS4-30I 制造商:Panduit Corp 功能描述:
LS4-31 制造商:Panduit Corp 功能描述:
LS431050 功能描述:SCR MOD ISO SGL 1000V 500A RoHS:是 类别:半导体模块 >> SCR 系列:- 其它有关文件:SCR Module Selection Guide 标准包装:10 系列:- 结构:串联 - SCR/二极管 SCR 数目,二极管:1 SCR,1 个二极管 电压 - 断路:1600V 电流 - 栅极触发电流 (Igt)(最大):150mA 电流 - 导通状态 (It (AV))(最大):95A 电流 - 导通状态 (It (RMS))(最大):210A 电流 - 非重复电涌,50、60Hz (Itsm):1785A,1870A 电流 - 维持(Ih):250mA 安装类型:底座安装 封装/外壳:ADD-A-PAK(3 + 2) 包装:散装 其它名称:*IRKL92/16AIRKL92/16IRKL92/16-ND
LS431250 功能描述:SCR MOD ISO SGL 1200V 500A RoHS:是 类别:半导体模块 >> SCR 系列:- 其它有关文件:SCR Module Selection Guide 标准包装:10 系列:- 结构:串联 - SCR/二极管 SCR 数目,二极管:1 SCR,1 个二极管 电压 - 断路:1600V 电流 - 栅极触发电流 (Igt)(最大):150mA 电流 - 导通状态 (It (AV))(最大):95A 电流 - 导通状态 (It (RMS))(最大):210A 电流 - 非重复电涌,50、60Hz (Itsm):1785A,1870A 电流 - 维持(Ih):250mA 安装类型:底座安装 封装/外壳:ADD-A-PAK(3 + 2) 包装:散装 其它名称:*IRKL92/16AIRKL92/16IRKL92/16-ND