参数资料
型号: LS5660-9PD4B2
元件分类: 电源模块
英文描述: 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
封装: METAL, CASE S02, MODULE
文件页数: 13/27页
文件大小: 599K
代理商: LS5660-9PD4B2
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
20/27
Table 13: Isolation
Characteristic
Input to
Output to Output to
Unit
case
output
case
output
Electric
Required according to
1.5
3.0 1
––
kVrms
strength
IEC/EN 60950
2.1
4.2 1
––
kV DC
test voltage
Actual factory test 1 s
2.8
5.6 1
1.4
0.14
AC test voltage equivalent
2.0
4.0 1
1.0
0.1
kVrms
to actual factory test
Insulation resistance at 500 V DC
>300
>100 2
M
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
2 Tested at 100 V DC.
For creepage distances and clearances refer to:
Technical Information: Safety.
Leakage Currents in AC-DC operation
Leakage currents flow due to internal leakage capacitance
and RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to
the mains frequency and are specified at an input voltage of
254 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment.
V
MI
500
1500
10 k
220 nF
22 nF
10061
Under test conditions the leakage current flows through a
measuring instrument (MI) as described in fig.:
Measuring
instrument for earth leakage current tests, which takes into
account impedance and sensitivity of a person touching
unearthed accessible parts. The current value is calculated
by dividing the measured voltage by 500
. If inputs of S-
units are connected in parallel, their individual leakage cur-
rents are added.
Fig. 28
Measuring instrument (MI) for earth leaking current tests
according to IEC/EN 60950.
Vo+
Vo–
N
P
10062
N
P
MI for
earth
leakage
current
Fig. 29
Test set-up
Standards and Approvals
All AC-DC converters correspond to class I equipment.
They are UL recognized according to UL 1950, UL recog-
nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA
approved to IEC/EN 60950 standards.
The units have been evaluated for:
Building in
Basic insulation between input and case, based on 250 V
AC and 400 V DC
Double or reinforced insulation between input and output,
based on 250 V AC and 400 V DC
Basic insulation between output and case based on
200 V AC and DC
Operational insulation between output and output
Connecting the input to a primary or secondary circuit
which is subject to a maximum transient rating of 2500 V
(overvoltage category III based on a 110 V primary cir-
cuit, overvoltage category II based on a 230 V primary
circuit).
The use in a pollution degree 2 environment
The UL 1950 recognition limits the minimum input voltage
to
Ui = Ui min + 5 V AC = 90 V AC if the case temperature
exceeds 90
°C.
The AC-DC converters are subject to manufacturing sur-
veillance in accordance with the above mentioned UL,
CSA, EN and with ISO 9001 standards.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Important: Testing by applying AC voltages will result in
high and dangerous leakage currents flowing through
the Y-capacitors (see fig.:
Block diagram).
相关PDF资料
PDF描述
LFB200S 1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
LSP3125SAE 7.5 A SWITCHING CONTROLLER, 173 kHz SWITCHING FREQ-MAX, PDSO8
LM5067SDX-1 2-CHANNEL POWER SUPPLY SUPPORT CKT, DSO10
LS4601-7ERD1TB1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
LS4601-7ERD5TB1 1-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
相关代理商/技术参数
参数描述
LS5-72 制造商:Panduit Corp 功能描述:
LS5-73 功能描述:打印机 LS5, Laminated Continuous Tape, Polyeste RoHS:否 制造商:Seiko Instruments 产品:Printer 电源电压: 每行点数:9 x 320 打印速度:52.5 cps, 80 cps 纸张宽度:112 mm
LS5-74 制造商:Panduit Corp 功能描述:
LS5-75 制造商:Panduit Corp 功能描述:
LS5761-3 制造商: 功能描述: 制造商:undefined 功能描述: