参数资料
型号: LSN2-T/10-D12C
厂商: MURATA POWER SOLUTIONS INC
元件分类: 电源模块
英文描述: 1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
封装: ROHS COMPLIANT, SIP-11
文件页数: 14/15页
文件大小: 302K
代理商: LSN2-T/10-D12C
LSN2 Series
Non-isolated, DOSA-SIP, 6/10/16A
Selectable-Output DC/DC Converters
www.murata-ps.com
email: sales@murata-ps.com
25 Jun 2010
MDC_LSN2.B07Δ Page 8 of 15
never absolutely constant, the converter may start up at some times and not
at others.
Solutions
To improve start up, review the conditions above. One of the better solutions
is to place a moderate size capacitor very close to the input terminals. You
may need two parallel capacitors. A larger electrolytic or tantalum cap sup-
plies the surge current and a smaller parallel low-ESR ceramic cap gives low
AC impedance. Too large an electrolytic capacitor may have higher internal
impedance (ESR) and/or lower the start up slew rate enough to upset the DC/
DC’s controller. Make sure the capacitors can tolerate reected switching cur-
rent pulses from the converter.
The capacitors will not help if the input source has poor regulation. A
converter which starts successfully at 3.3 Volts will turn off if the input voltage
decays to below the input voltage theshold, regardless of external capacitance.
Increase the input start up voltage if possible to raise the downward voltage
spike. Also, make sure that the input voltage ramps up in a reasonably short
time (less than a few milliseconds). If possible, move the input source closer
to the converter to reduce ohmic losses in the input wiring. Remember that
the input current is carried both by the wiring and the ground plane return.
Make sure the ground plane uses adequate thickness copper. Run additional
bus wire if necessary.
Any added output capacitor should use just enough capacitance (and
no more) to reduce output noise at the load and to avoid marginal thresh-
old noise problems with external logic. An output cap will also “decouple”
inductive reactance in the load. Certain kinds of electronic loads include
“constant current” characteristics which destabilize the output with insuf-
cient capacitance. If the wiring to the eventual load is long, consider placing
this decoupling cap at the load. Use the Remote Sense input to avoid ohmic
voltage drop errors.
An elegant solution to start up problems is to apply the input voltage with
the Remote On/Off control rst in the off setting (for those converters with an
On/Off Control). After the specied start-up delay (usually under 20 mSec),
turn on the converter. The controller will have already been stabilized. The
short delay will not be noticed in most applications. Be aware of applications
which need “power management” (phased start up).
Finally, it is challenging to model some application circuits with absolute
delity. How low is the resistance of your ground plane? What is the inductance
(and distributed capacitance) of external wiring? Even a detailed mathematical
model may not get all aspects of your circuit. Therefore it is difcult to give cap
values which serve all applications. Some experimentation may be required.
Pre-Biased Startup
Newer systems with multiple power voltages have an additional problem
besides startup sequencing. Some sections have power already partially ap-
plied (possibly because of earlier power sequencing) or have leakage power
present so that the DC/DC converter must power up into an existing voltage.
This power may either be stored in an external bypass capacitor or supplied
by an active source.
This “pre-biased” condition can also occur with some types of program-
mable logic or because of blocking diode leakage or small currents passed
The highest temperatures in LSN2 SIPs occur at their output inductor,
whose heat is generated primarily by I2R losses. The derating curves were
developed using thermocouples to monitor the inductor temperature and
varying the load to keep that temperature below +110°C under the assorted
conditions of air ow and air temperature. Once the temperature exceeds
+115°C (approx.), the thermal protection will disable the converter. Automatic
restart occurs after the temperature has dropped below +110°C.
As you may deduce from the derating curves and observe in the efciency
curves on the following pages, LSN2 SIPs maintain virtually constant efcien-
cy from half to full load, and consequently deliver very impressive temperature
performance even if operating at full load.
Lastly, when LSN2 SIPs are installed in system boards, they are obviously
subject to numerous factors and tolerances not taken into account here. If you
are attempting to extract the most current out of these units under demand-
ing temperature conditions, we advise you to monitor the output-inductor
temperature to ensure it remains below +110°C at all times.
Start Up Considerations
When power is rst applied to the DC/DC converter, operation is different than
when the converter is running and stabilized. There is some risk of start up
difculties if you do not observe several application features. Lower output
voltage converters may have more problems here since they tend to have
higher output currents. Operation is most critical with any combination of the
following external factors:
1 – Low initial input line voltage and/or poor regulation of the input source.
2 – Full output load current on lower output voltage converters.
3 – Slow slew rate of input voltage.
4 – Longer distance to input voltage source and/or higher external input
source impedance.
5 – Limited or insufcient ground plane. External wiring that is too small.
6 – Too small external input capacitance. Too high ESR.
7 – High output capacitance causing a start up charge overcurrent surge.
8 – Output loads with excessive inductive reactance or constant current
characteristics.
If the input voltage is already at the low limit before power is applied, the
start up surge current may instantaneously reduce the voltage at the input
terminals to below the specied minimum voltage. Even if this voltage depres-
sion is very brief, this may interfere with the on-board controller and possibly
cause a failed start. Or the converter may start but the input current load will
now drive the input voltage below its running low limit and the converter will
shut down.
If you measure the input voltage before start up with a Digital Voltmeter (DVM),
the voltage may appear to be adequate. Limited external capacitance and/or
too high a source impedance may cause a short downward spike at power up,
causing an instantaneous voltage drop. Use an oscilloscope not a DVM to observe
this spike. The converter’s soft-start controller is sensitive to input voltage. What
matters here is the actual voltage at the input terminals at all times.
Symptoms of start-up difculties may include failed started, output oscil-
lation or brief start up then overcurrent shutdown. Since the input voltage is
相关PDF资料
PDF描述
LSP3102QAD 1.45 A SWITCHING REGULATOR, 1800 kHz SWITCHING FREQ-MAX, QCC16
LSP3102Y12AD 1.45 A SWITCHING REGULATOR, 1800 kHz SWITCHING FREQ-MAX, PDSO5
LSP3102Y18AD 1.45 A SWITCHING REGULATOR, 1800 kHz SWITCHING FREQ-MAX, PDSO5
LSP3102Q18AD 1.45 A SWITCHING REGULATOR, 1800 kHz SWITCHING FREQ-MAX, QCC16
LSP3112LAD SWITCHING REGULATOR, PDSO10
相关代理商/技术参数
参数描述
LSN2T10W3C 制造商:Datel 功能描述:
LSN2-T30-D12 制造商:MURATA 制造商全称:Murata Manufacturing Co., Ltd. 功能描述:DOSA-SIP, 30A POL DC/DC Converters
LSN2-T30-D12-C 制造商:MURATA 制造商全称:Murata Manufacturing Co., Ltd. 功能描述:DOSA-SIP, 30A POL DC/DC Converters
LSN2-T30-D12G-C 制造商:MURATA 制造商全称:Murata Manufacturing Co., Ltd. 功能描述:DOSA-SIP, 30A POL DC/DC Converters
LSN-3.3/10-D12 功能描述:DC/DC转换器 33W 12V to 3.3V 10A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: