LV5122T
No.A0728-8/10
0V cell charge
If the cell voltage is 0V but a potential difference between VDD and V becomes equal to or greater than the 0V cell
charging lowest operation voltage, the Cout pin will output “H” and enable charging.
Test time reduction function
By turning T pin to the VDD potential, the delay times set by the counter can be cut. Normal time settings if T pin is
open. Delay time not set by the counter cannot be controlled by this pin.
Operation in case of detection overlap
Overlap state
Operation in case of
detection overlap
State after detection
When, during over-
charge detection,
Over-discharge
detection is made,
Over-charge detection is preferred. If over-
discharge state continues even after over-
charge detection, over-discharge detection is
resumed.
When over-charge detection is made first, V- is
released. When over-discharge is detected
after over-charge detection, the standby state is
not effectuated. Note that V- is connected to
VDD via 200k.
Over-current
detection is made,
(*1) Both detections’ can be made in parallel.
Over-charge detection continues even when the
over-current state occurs. If the over-charge
state occurs first, over-current detection is
interrupted.
(*2) When over-current is detected first, V- is
connected to VSS via 1M. When over-charge
detection is made first, V- is released.
When, during over-
discharge detection,
Over-charge detection
is made,
Over-discharge detection is interrupted and
over-charge detection is preferred. When over-
discharge state continues even after over-
charge detection, over-discharge detection is
resumed.
The standby state is not effectuated when over-
discharge detection is made after over-charge
detection. Note that V- is connected to VDD via
200k.
Over-current
detection is made,
(*3) Both detections can be made in parallel.
Over-discharge detection continues even when
the over-current state is effectuated first. Over-
current detection is interrupted when the over-
discharge state is effectuated first,
(*4) If over-current is detected in advance, V will
be connected to VSS via 1M. After detecting
over-discharge, V will be connected to VDD via
200k to get into standby state. If over-
discharge is detected in advance, V will be
connected to VDD via 200k to get into standby
state.
Over-charge detection
is made,
(*1)
(*2)
When, during over-
current detection,
Over-discharge
detection is made,
(*3)
(*4)
(Note) Short-circuit detection can be made independently.