参数资料
型号: MAX3056ASD+T
厂商: Maxim Integrated Products
文件页数: 6/18页
文件大小: 0K
描述: IC TXRX CAN FP 14-SOIC
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
类型: 收发器
驱动器/接收器数: 1/1
规程: CAN
电源电压: 4.75 V ~ 5.25 V
安装类型: 表面贴装
封装/外壳: 14-SOIC(0.154",3.90mm 宽)
供应商设备封装: 14-SOIC
包装: 带卷 (TR)
MAX3054/MAX3055/MAX3056
±80V Fault-Protected/Tolerant CAN
Transceivers for In-Car Applications
14
______________________________________________________________________________________
MODE
DESCRIPTION
Detection
Sensing a permanent dominant condition on CANH for a timeout period.
Receiver
Receiver switches to single ended on CANL.
Driver
CANH and RTH are both switched off (high impedance) and transmission continues on CANL after timeout.
Recovery
When the short is removed, the recessive bus voltage is restored. If the differential voltage remains below the
recessive threshold level for the timeout period, reception and transmission switch back to the differential mode.
Table 1. Failure States (continued)
Failure 3—CANH Short Circuited to Battery
MODE
DESCRIPTION
Detection
Sensing a permanent dominant condition for a timeout period.
Receiver
Receiver switches to single ended on CANH.
Driver
CANL and RTL are both switched off (high impedance) and transmission continues on CANH after timeout.
Recovery
When the short is removed, the recessive bus voltage is restored. If the differential voltage remains below the
recessive threshold level for the timeout period, reception and transmission switch back to the differential mode.
Failure 4—CANL Short Circuited to GND
MODE
DESCRIPTION
Detection
Detection is provided, sensing the pulse-count difference between CANH and CANL (pulse count = 4).
Receiver
Receiver remains in differential mode. No received data lost.
Driver
RTH remains on and CANH remains enabled.
Recovery
Recovery is provided, sensing the edge-count difference between CANH and CANL after the detection of four
consecutive pulses.
Failure 5—CANH Short Circuited to Ground or Below Ground (Normal Mode Only)
MODE
DESCRIPTION
Detection
Detected by a comparator for CANL > 7.3V after a timeout period.
Receiver
Receiver switches to single ended on CANH after timeout.
Driver
RTL is switched off after timeout. CANH remains active.
Recovery
Sensing CANL < 7.3V after the timeout period.
Failure 6—CANL Short Circuited to Battery (Normal Mode Only)
MODE
DESCRIPTION
Detection
Sensing a permanent dominant condition on the differential comparator (CANH - CANL > -3.2V) for the timeout
period.
Receiver
Receiver switches to CANH single-ended mode after timeout.
Driver
CANL and RTL are both switched off after timeout. Transmission remains ongoing on CANH.
Recovery
When the short is removed, the recessive bus voltage is restored (RTL on if CANH - CANL < -3.2V) but CANL still
remains disabled and ERR = 0. If the differential voltage remains below the recessive threshold level (CANH -
CANL < -3.2V) for the timeout period, reception and transmission switch back to the differential mode.
Failure 7—CANL Mutually Short Circuited to CANH
相关PDF资料
PDF描述
MS27497T22F21P CONN RCPT 21POS WALL MNT W/PINS
MAX13413EESA+T IC TXRX RS-485 LDO/CTRL 8-SOIC
MS27484T14B15P CONN PLUG 15POS STRAIGHT W/PINS
MAX3301EETJ+T IC USB TXRX OTG 32-TQFN-EP
MS27473T16A8PA CONN PLUG 8POS STRAIGHT W/PINS
相关代理商/技术参数
参数描述
MAX3057ASA 功能描述:CAN 接口集成电路 RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MAX3057ASA+ 功能描述:CAN 接口集成电路 80V Fault-Protected 2Mbps RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MAX3057ASA+T 功能描述:CAN 接口集成电路 80V Fault-Protected 2Mbps RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MAX3057ASA-T 功能描述:CAN 接口集成电路 RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube
MAX3058ASA 功能描述:CAN 接口集成电路 RoHS:否 制造商:Texas Instruments 类型:Transceivers 工作电源电压:5 V 电源电流: 工作温度范围:- 40 C to + 85 C 封装 / 箱体:SOIC-8 封装:Tube