参数资料
型号: MAX3250CAI+T
厂商: Maxim Integrated Products
文件页数: 9/10页
文件大小: 0K
描述: IC TXRX RS-232 250KBPS 28-SSOP
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,000
类型: 收发器
驱动器/接收器数: 2/2
规程: RS232
电源电压: 3 V ~ 5.5 V
安装类型: 表面贴装
封装/外壳: 28-SSOP(0.209",5.30mm 宽)
供应商设备封装: 28-SSOP
包装: 带卷 (TR)
MAX3250
±50V Isolated, 3.0V to 5.5V,
250kbps, 2 TX/2 RX, RS-232 Transceiver
8
_______________________________________________________________________________________
To achieve full isolation capability, C1, C2, and C9
should be rated for 100V or higher operation and be X7R
or X5R type or metalized film dielectric. Y5V and Z5U
dielectrics should be avoided as their voltage and tem-
perature coefficients make their power-transfer capabili-
ties insufficient.
Charge-Pump and Bypass Capacitors
Capacitors C3–C8 should be X7R or X5R type dielec-
tric. Their voltage rating needs to be 10V or higher.
Layout Information
Because the MAX3250 is intended for systems requir-
ing ±50V isolation, some consideration in component
placement is necessary.
A 20mil air gap should isolate the logic side and the
isolated RS-232 side, across the N.C. pins (pin num-
bers 6, 7, 22, and 23) of the MAX3250. The only com-
ponents that cross this air gap should be C1, C2, and
C9, which should all have a minimum 100V rating.
All capacitors should be located as close to the
MAX3250 as possible.
Maximum Voltage Between
ISOCOM and Logic GND
High values of applied isolation voltage and frequency
can cause ripple on ISOVCC, V+, V-, and in extreme
cases on VCC. Therefore, it is recommended that the
isolation-voltage and frequency be limited to the values
shown in the
Typical Operating Characteristics.
Insert a 1k
1/4W resistor in series with any isolation
test voltage when testing for maximum values of
applied isolation voltage. Exceeding the maximum lim-
its of voltage and frequency (see the
Typical Operating
Characteristics) could trigger a holding current in the
internal ESD-protection device if the ±80V isolation limit
is exceeded. This resistor should not be used in normal
application.
Transmitter Outputs when
Exiting Shutdown
Figure 3 shows two transmitter outputs when exiting
shutdown mode. As they become active, the two trans-
mitter outputs are shown going to opposite RS-232 lev-
els (one transmitter input is high, the other is low). Each
transmitter is loaded with 3k
in parallel with 2500pF.
The transmitter outputs display no ringing or undesir-
able transients as they come out of shutdown. Note that
the transmitters are enabled only when the magnitude
of V- exceeds approximately -3V.
VCC (V)
C1, C2 (F)
C3 (F)
C4, C7, C8 (F)
C5 (F)
C6 (F)
C9 (nF)
3.0 to 3.6
0.47
0.1
0.47
1
2.2
10
4.5 to 5.5
0.047
0.1
0.47
1
2.2
10
Table 1. Required Capacitor Values
相关PDF资料
PDF描述
SN74ABT8952DWRE4 IC SCAN TESST DEVICE 28-SOIC
MS27508E18B35PA CONN RCPT 66POS BOX MNT W/PINS
MS27499E24A35S CONN RCPT 128POS BOX MNT W/SCKT
VI-2N2-IU-F3 CONVERTER MOD DC/DC 15V 200W
IL3285 IC TXRX RS485 ISOLATED 16SOICW
相关代理商/技术参数
参数描述
MAX3250EAI 功能描述:RS-232接口集成电路 RoHS:否 制造商:Exar 数据速率:52 Mbps 工作电源电压:5 V 电源电流:300 mA 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体:LQFP-100 封装:
MAX3250EAI+ 功能描述:RS-232接口集成电路 3-5.5V 250kbps Transceiver RoHS:否 制造商:Exar 数据速率:52 Mbps 工作电源电压:5 V 电源电流:300 mA 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体:LQFP-100 封装:
MAX3250EAI+ 制造商:Maxim Integrated Products 功能描述:IC RS232 TRANSCEIVER 250KBPS 5
MAX3250EAI+T 功能描述:RS-232接口集成电路 3-5.5V 250kbps Transceiver RoHS:否 制造商:Exar 数据速率:52 Mbps 工作电源电压:5 V 电源电流:300 mA 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体:LQFP-100 封装:
MAX3250EAI-T 功能描述:RS-232接口集成电路 RoHS:否 制造商:Exar 数据速率:52 Mbps 工作电源电压:5 V 电源电流:300 mA 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体:LQFP-100 封装: