MAX34440
PMBus 6-Channel Power-Supply Manager
Fault Management and Reporting
For reporting faults/warnings to the host on a real-time
basis, the device asserts the open-drain ALERT pin (if
enabled in MFR_MODE) and sets the appropriate bit in
the various status registers. On recognition of the ALERT
assertion, the host or system manager is expected to poll
the I 2 C bus to determine the device asserting ALERT .
The host sends the SMBus ARA (0001 100). The device
ACKs the SMBus ARA, transmits its slave address, and
deasserts ALERT . The system controller then communi-
cates with PMBus commands to retrieve the fault/warn-
ing status information from the device.
See the individual command sections for more details.
Faults and warnings that are latched in the status regis-
ters are cleared when any one of the following conditions
occurs:
?  A CLEAR_FAULTS command is received.
?  The  RST pin is toggled.
?  Bias power to the device is removed and then reapplied.
One or more latched-off power supplies is only restarted
when one of the following occurs:
?  The  output  is  commanded  through  the  CONTROL 
pin, the OPERATION command, or the combined
action of the CONTROL pin and OPERATION com-
mand to turn off and then turn back on.
?  The  RST pin is toggled.
?  Bias power to the device is removed and then reapplied.
A power supply is not allowed to turn on if any faults the
supply responds to are detected. Only after the faults
Table 5. Devic e Parametric Monitoring States
clear is the power supply allowed to turn on. When global
supplies are being sequenced on, a fault on any of the
supplies keeps all supplies from being turned on.
A system-wide power-up (OPERATION command is
received to turn the supplies on when PAGE is 255 or the
CONTROL pin is toggled to turn on the supplies) allows
all enabled power supplies to power-up. If any faults are
detected once the supplies start to turn on, the response
of MFR_FAULT_RESPONSE is performed.
The device responds to fault conditions accord-
ing to the manufacturer fault response command
(MFR_FAULT_RESPONSE). This command byte deter-
mines how the device should respond to each particular
fault. Table 5 illustrates the required conditions and fault
actions for specific parameters.
System Watchdog Timer
The device uses an internal watchdog timer that is inter-
nally reset every 5ms. In the event that the device is
locked up and this watchdog reset does not occur after
500ms, the device automatically resets. After the reset
occurs, the device reloads all configuration values that
were stored to flash and begins normal operation. After
the reset, the device also does the following:
1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE.
2) Sets the NONE OF THE ABOVE and MFR bits in
STATUS_WORD.
3) Sets the WATCHDOG bit in STATUS_MFR_SPECIFIC.
4) Notifies the host through ALERT assertion (if enabled
in MFR_MODE).
PARAMETER
Overvoltage
REQUIRED CONDITIONS FOR ACTIVE MONITORING
Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h)
ACTION DURING A FAULT
Continue Monitoring
Undervoltage
?  
?  
?  
Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h)
PSEN Output is Active
Channel’s VOUT Must Have Exceeded VOUT_UV_FAULT During
Stop Monitoring While the Power
Supply is Off
Channel Power-Up
Overcurrent
?  
?  
Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h)
Current Monitoring Enabled (IOUT_OC_FAULT_LIMIT ≠ 0000h)
Continue Monitoring
Power-Up Time
Overtemperature
Maxim Integrated
Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h)
Temp Sensor Enabled (ENABLE in MFR_TEMP_SENSOR_CONFIG = 1)
Monitor Only During Power-On
Continue Monitoring
21
相关PDF资料
PDF描述
HCC07DRXN-S734 CONN EDGECARD 14POS DIP .100 SLD
GSC12DRYI CONN EDGECARD 24POS DIP .100 SLD
462W023-25-0 BOOT MOLDED
V24B24E150B3 CONVERTER MOD DC/DC 24V 150W
RNF-100-3/32-BU-STK HEAT SHRINK TUBING
相关代理商/技术参数
参数描述
MAX34440ETL+ 功能描述:监控电路 PMBus 6Ch Power Supply Manager RoHS:否 制造商:STMicroelectronics 监测电压数: 监测电压: 欠电压阈值: 过电压阈值: 输出类型:Active Low, Open Drain 人工复位:Resettable 监视器:No Watchdog 电池备用开关:No Backup 上电复位延迟(典型值):10 s 电源电压-最大:5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:UDFN-6 封装:Reel
MAX34440ETL+T 功能描述:监控电路 PMBus 6Ch Power Supply Manager RoHS:否 制造商:STMicroelectronics 监测电压数: 监测电压: 欠电压阈值: 过电压阈值: 输出类型:Active Low, Open Drain 人工复位:Resettable 监视器:No Watchdog 电池备用开关:No Backup 上电复位延迟(典型值):10 s 电源电压-最大:5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:UDFN-6 封装:Reel
MAX34441ETL+ 功能描述:监控电路 PMBus 6Ch Power Supply Manager RoHS:否 制造商:STMicroelectronics 监测电压数: 监测电压: 欠电压阈值: 过电压阈值: 输出类型:Active Low, Open Drain 人工复位:Resettable 监视器:No Watchdog 电池备用开关:No Backup 上电复位延迟(典型值):10 s 电源电压-最大:5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:UDFN-6 封装:Reel
MAX34441ETL+T 功能描述:监控电路 PMBus 6Ch Power Supply Manager RoHS:否 制造商:STMicroelectronics 监测电压数: 监测电压: 欠电压阈值: 过电压阈值: 输出类型:Active Low, Open Drain 人工复位:Resettable 监视器:No Watchdog 电池备用开关:No Backup 上电复位延迟(典型值):10 s 电源电压-最大:5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:UDFN-6 封装:Reel
MAX34441EVKIT# 功能描述:电源管理IC开发工具 MAX34441 Eval Kit RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V