参数资料
型号: MAX4794ETT+T
厂商: Maxim Integrated Products
文件页数: 9/11页
文件大小: 0K
描述: IC SWITCH 1X1 6TDFN
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
功能: 开关
电路: 1 x 1:1
导通状态电阻: 400 毫欧
电压电源: 单电源
电压 - 电源,单路/双路(±): 2.3 V ~ 5.5 V
电流 - 电源: 80µA
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 6-WDFN 裸露焊盘
供应商设备封装: 6-TDFN 裸露焊盘(3x3)
包装: 带卷 (TR)
off.
FLAG is an open-drain output transistor and requires
an external pullup resistor from
FLAG to IN. During shut-
down (ON is low), the pulldown on
FLAG output is
released in order to limit power dissipation.
FLAG goes
low when any of the following conditions occur:
The die temperature exceeds the thermal-shutdown
temperature limit of +150°C.
The device is in current limit for more than the fault-
blanking period.
VIN is below UVLO threshold.
Autoretry (MAX4790/MAX4792/MAX4794)
When the forward or reverse current-limit threshold is
exceeded, tBLANK timer begins counting (Figure 2).
The timer resets if the overcurrent condition disappears
before tBLANK has elapsed. A retry time delay, tRETRY,
is started immediately after tBLANK has elapsed and
during that time, the switch is latched off. At the end of
tRETRY, the switch is turned on again. If the fault still
exists, the cycle is repeated. If the fault has been
removed, the switch stays on.
The autoretry feature saves system power in the case of
an overcurrent or short-circuit condition. During tBLANK,
when the switch is on, the supply current is at the cur-
rent limit. During tRETRY, when the switch is off, the cur-
rent through the switch is zero. Instead of observing the
full load current, the switch sees the equivalent load
current times duty cycle or ISUPPLY = ILOAD
tBLANK/(tBLANK + tRETRY). With a typical tBLANK =
37ms and typical tRETRY = 259ms, the duty cycle is
12%, which results in an 88% power savings over the
switch being on the entire time. The duty cycle is con-
sistent across the process and devices.
Latch Off (MAX4789/MAX4791/MAX4793)
When the forward or reverse current-limit threshold is
exceeded, tBLANK timer begins counting. The timer
resets if the overcurrent condition disappears before
tBLANK has elapsed. The switch is shut off if the over-
current condition continues up to the end of the blank-
ing time. Reset the switch by either toggling ON (Figure
3a) or cycling the input voltage below UVLO, typically
2V (Figure 3b).
Fault Blanking
The MAX4789–MAX4794 feature 14ms (min) fault blank-
ing. Fault blanking allows current-limit faults, including
momentary short-circuit faults that occur when hot
swapping a capacitive load, and also ensures that no
fault is issued during power-up. When a load transient
causes the device to enter current limit, an internal
counter starts. If the load-transient fault persists beyond
the fault-blanking timeout, the MAX4789/MAX4791/
MAX4793
FLAG asserts low. Load-transient faults less
than tBLANK do not cause a FLAG output assertion. Only
current-limit faults are blanked.
A thermal fault and input voltage drops below the UVLO
threshold cause
FLAG to assert immediately and do not
wait for the blanking time.
Thermal Shutdown
The MAX4789–MAX4794 have a thermal shutdown fea-
ture to protect the devices from overheating. The switch
turns off and
FLAG goes low immediately (no fault blank-
ing) when the junction temperature exceeds +150°C.
The switch turns back on when the device temperature
drops approximately 15°C.
MAX4789–MAX4794
200mA/250mA/300mA Current-Limit Switches
_______________________________________________________________________________________
7
ON
FAULT
SWITCH ON/OFF
SUPPLY CURRENT MODE
Low
X
OFF
Shutdown
High
Undervoltage Lockout
OFF
Shutdown
High
Thermal
OFF immediately (tBLANK period does not apply)
Latch off
OFF after tBLANK period has elapsed
Latch off
High
Current Limit
ON during tBLANK period, OFF during tRETRY period for the
MAX4790, MAX4792, and MAX4794; cycle repeats until fault
is removed
See the Autoretry section
Table 1. MAX4789–MAX4794 Switch Truth Table
LOAD
CURRENT
SWITCH
STATUS
tBLANK
OFF
ON
tRETRY
CURRENT
LIMIT
SHORT
CONDITION
REMOVED
tBLANK
Figure 2. MAX4790/MAX4792/MAX4794 Autoretry Fault
Blanking Diagram
相关PDF资料
PDF描述
VI-B1T-IY-F1 CONVERTER MOD DC/DC 6.5V 50W
MAX4789ETT+T IC SWITCH 1X1 6TDFN
VI-21T-IY-F4 CONVERTER MOD DC/DC 6.5V 50W
VE-BND-IW-F4 CONVERTER MOD DC/DC 85V 100W
MAX4829ELT+T IC SWITCH 1X1 6UTDFN
相关代理商/技术参数
参数描述
MAX4794EUS+ 制造商:Maxim Integrated Products 功能描述:CURRENT LIMIT SW 1-IN 1-OUT 2.3V TO 5.5V 0.45A 4PIN SOT-143 - Rail/Tube
MAX4794EUS+T 功能描述:电源开关 IC - 配电 200/250/300mA Crnt Limit Switch RoHS:否 制造商:Exar 输出端数量:1 开启电阻(最大值):85 mOhms 开启时间(最大值):400 us 关闭时间(最大值):20 us 工作电源电压:3.2 V to 6.5 V 电源电流(最大值): 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:SOT-23-5
MAX4794EUS-T 功能描述:电源开关 IC - 配电 RoHS:否 制造商:Exar 输出端数量:1 开启电阻(最大值):85 mOhms 开启时间(最大值):400 us 关闭时间(最大值):20 us 工作电源电压:3.2 V to 6.5 V 电源电流(最大值): 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:SOT-23-5
MAX4795ETT-T 功能描述:电源开关 IC - 配电 RoHS:否 制造商:Exar 输出端数量:1 开启电阻(最大值):85 mOhms 开启时间(最大值):400 us 关闭时间(最大值):20 us 工作电源电压:3.2 V to 6.5 V 电源电流(最大值): 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:SOT-23-5
MAX4795EUK 制造商:Maxim Integrated Products 功能描述:- Cut Tape Product