A
MAX6342–MAX6345
6-Pin P Reset Circuit with
Power-Fail Comparator
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC = +1.0V to +5.5V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at TA = +25°C and VCC = +3V.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VCC to GND ..............................................................-0.3V to +6V
RESET, RESET
(MAX6342/MAX6344/MAX6345) ......... -0.3V to (VCC + 0.3V)
RESET (MAX6343)................................................... -0.3V to +6V
MR, PFI, PFO ..............................................-0.3V to (VCC + 0.3V)
Input Current, VCC ..............................................................50mA
Output Current, RESET, RESET ..........................................50mA
Continuous Power Dissipation (TA = +70°C)
6-Pin SOT23 (derate 4mW/°C above +70°C).............320mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature Range (soldering, 10s)..................... +300°C
V
VCC > 1.2V, ISINK = 100A
0.4
VOL
RESET and RESET
Outputs Drive
Capability (Note 2)
TA = -40°C to +85°C
2.25
2.38
TA = -40°C to +125°C
2.21
2.45
MAX634_Z
MAX634_S
MAX634_T
MAX634_M
TA = +25°C
TA = -40°C to +125°C
TA = -40°C to +85°C
TA = +25°C
2.50
2.76
MAX634_R
2.59
2.63
2.67
2.55
2.70
2.30
2.33
2.36
TA = -40°C to +125°C
TA = -40°C to +85°C
TA = +25°C
TA = -40°C to +125°C
2.85
3.00
2.92
3.23
2.89
2.93
2.97
2.78
3.08
TA = -40°C to +85°C
TA = +25°C
TA = -40°C to +125°C
TA = -40°C to +85°C
3.03
3.08
3.13
4.25
4.50
4.16
4.56
3.00
3.15
TA = +25°C
TA = -40°C to +125°C
TA = -40°C to +85°C
TA = +25°C
4.40
4.86
V
MAX634_L
4.56
4.63
4.70
VTH
Reset Threshold
4.50
4.75
4.31
4.38
4.45
30
60
VCC = 5.5V, TA = -40° to +125°C
VCC = 3V, TA = -40° to +125°C
VCC = 5.5V, TA = -40° to +85°C
VCC = 3V, TA = -40° to +85°C
25
50
TA = -40°C to +125°C
TA = 0°C to +70°C
VCC = VTH to (VTH - 100mV)
A
No load
CONDITIONS
s
20
VCC to Reset Delay
25
40
ICC
Supply Current
1.2
5.5
V
1.0
5.5
VCC
Supply Voltage Range
30
50
UNITS
MIN
TYP
MAX
SYMBOL
PARAMETER
VCC > 2.7V, ISINK = 1.2mA
VCC > 4.5V, ISINK = 3.2mA
0.4
0.3
V
0.8
VCC
VCC > 1.2V, ISOURCE = 50A
0.8
VCC
VCC > 2.7V, ISOURCE = 500A
(MAX6342/MAX6345 only)
0.8
VCC
VCC > 4.5V, ISOURCE = 800A
(MAX6342/MAX6345 only)
VOH