参数资料
型号: MAX66020K-000AA+
厂商: Maxim Integrated
文件页数: 10/25页
文件大小: 0K
描述: IC RFID UID 1KB TYPEB MEM KEYFOB
产品培训模块: Lead (SnPb) Finish for COTS
产品变化通告: Product Discontinuation 06/Feb/2012
标准包装: 1
系列: iButton®
RF 型: 读/写
频率: 13.56MHz
特点: ISO14443-B
封装/外壳: 遥控钥匙
供应商设备封装: 遥控钥匙
包装: 散装
ISO/IEC 14443 Type B-Compliant
1Kb Memory Fob
the master that the response is going to take longer than
MSb
BIT 8
1
BIT 7
1
BIT 6
BIT 5
BIT 4
CID
BIT 3
0
BIT 2
1
LSb
BIT 1
0
specified by the frame-waiting time (FWT) (see the
ATQB Response section). However, the MAX66020
does not use this feature and consequently, the only use
of the S-block is to transition the device from the ACTIVE
state to the HALT state using the DESELECT command
Figure 14. Bit Assignments for S-Block PCB
(see the Network Function Commands section).
Card Identifier
MSb
BIT 8 BIT 7
0 0
(POWER LEVEL)
BIT 6 BIT 5
0 0
(FIXED)
BIT 4 BIT 3 BIT 2 BIT 1
CARD IDENTIFIER VALUE
LSb
Figure 15 shows the bit assignment within the card
identifier byte. The purpose of bits 4 to 1 is to select
one of multiple slave devices that the master has ele-
vated to the ACTIVE state. The CID is assigned to a
slave through Param 4 of the ATTRIB command (see
the Network Function Commands section). While in
Figure 15. Bit Assignments for CID Byte in I-Blocks
ACTIVE state, a compliant slave only processes blocks
that contain a matching CID and blocks without CID if
the assigned CID is all zeros. If the master includes a
SOF
PCB
CID
INFORMATION FIELD
CRC (LSB) CRC (MSB)
EOF
CID, then the slave’s response also includes a CID
byte. Blocks with a nonmatching CIDs are ignored.
According to the standard, the slave can use bits 8 and
Figure 16. Frame Format for Block Transmission Protocol
the block number field. The block number is used to
ensure that the response received relates to the
request sent. This function is important in the error han-
dling, which is illustrated in Annex B of ISO/IEC 14443-
4. The rules that govern the numbering and handling of
blocks are found in Sections 7.5.3 and 7.5.4 of
ISO/IEC 14443-4. The MAX66020 ignores I-blocks that
have bit 5 or bit 3 set to 1.
For R-blocks, the states of bit 2, bit 3, bit 6, bit 7, and
bit 8 are fixed and must be transmitted as shown in
Figure 13. The function of bit 1 (block number) and bit 4
(CID indicator) is the same as for I-blocks. Bit 5,
marked as AN, is used to acknowledge (if transmitted
as 0) or not to acknowledge (if transmitted as 1) the
reception of the last frame for recovery from certain
error conditions. The MAX66020 fully supports the func-
tion of the R-block as defined in the standard. For
details and the applicable rules, refer to Sections 7.5.3
and 7.5.4 and Annex B of ISO/IEC 14443-4.
For S-blocks, the states of bit 1, bit 2, bit 3, and bit 7
and bit 8 are fixed and must be transmitted as shown in
Figure 14. The function of bit 4 (CID indicator) is the
same as for I-blocks. Bit 5 and bit 6, when 00b, specify
whether the S-block represents a deselect command. If
bit 5 and bit 6 are 11b, the S-block represents a frame-
waiting time extension (WTX) request, a feature to tell
7 to inform the master whether power-level indication is
supported, and, if yes, whether sufficient power is avail-
able for full functionality. Since the MAX66020 does not
support power-level indication, the power-level bits are
always 00b. When the master transmits a CID byte, the
power-level bits must be 00b.
Information Field
Since the MAX66020 does not generate WTX requests,
the information field (Figure 11) is found only with
I-blocks. The length of the information field is calculated
by counting the number of bytes of the whole block
minus length of prologue and epilogue field. The
ISO/IEC 14443 standard does not define any rules for
the contents of the information field. The MAX66020
assumes that the first byte it receives in the information
field is a command code followed by 0 or more com-
mand-specific parameters. When responding to an
I-block, the first byte of the information field indicates
success (code 00h) followed by command-specific
data or failure (code 01h) followed by one error code.
Memory and Control
Function Commands
The commands described in this section are transmit-
ted using the block transmission protocol. The data of a
block (from prologue to epilogue) is embedded
between SOF and EOF, as shown in Figure 16. The CID
field (shaded) is optional. If the request contains a CID,
the response also contains a CID.
10
______________________________________________________________________________________
相关PDF资料
PDF描述
MAX66040K-000AA+ ISO CARD SECURE MEMORY
MAX6605MXK/V+T IC TEMP SENSOR ANLG LP SC70-5
MAX6608IUK+T IC TEMP SENSOR ANLG SOT23-5
MAX66100K-000AA+ IC RFID UID 64BIT TYPE B KEY FOB
MAX6611AUT+T IC TEMP SENS LOW PWR SOT23-6
相关代理商/技术参数
参数描述
MAX66020K-000AA+ 功能描述:RFID应答器 ISO/IEC 14443 Type B Comp 1Kb Mem Fob RoHS:否 制造商:Murata 存储容量:512 bit 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体: 封装:Reel
MAX66020K-00AA+ 制造商:Maxim Integrated Products 功能描述:ISO/IEC 14443 TYPE B-COMPLIANT 1KB MEMORY FOB - Rail/Tube
MAX6602UE9A+ 功能描述:板上安装温度传感器 5Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6602UE9A+T 功能描述:板上安装温度传感器 5Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6603ATB 制造商:Maxim Integrated Products 功能描述:DUAL-CHANNEL PLATINUM RTD-TO-VOLTAG - Rail/Tube