参数资料
型号: MAX6692MUA+
厂商: Maxim Integrated
文件页数: 3/16页
文件大小: 194K
描述: IC SENSOR REMOTE SMBUS 8UMAX
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 50
功能: 温度监控系统(传感器)
传感器类型: 内部和外部
感应温度: 0°C ~ 125°C,外部传感器
精确度: ±3°C(最小值)
拓扑: ADC,多路复用器,寄存器库
输出类型: I²C?/SMBus?
输出警报:
输出风扇:
电源电压: 3 V ~ 5.5 V
工作温度: -55°C ~ 125°C
安装类型: 表面贴装
封装/外壳: 8-TSSOP,8-MSOP(0.118",3.00mm 宽)
供应商设备封装: 8-uMAX
包装: 管件
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
______________________________________________________________________________________________________________________________________________________________________________   3
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 3.0V to 5.5V, T
A
= -55癈 to +125癈, unless otherwise specified. Typical values are at V
CC
= 3.3V and T
A
= +85癈.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
High level
80
100
120
Remote-Diode Source Current
I
RJ
Low level
8
10
12
ALERT, OVERT
I
SINK
 = 1mA
0.4
Output Low Voltage
I
SINK
 = 4mA
0.6
V
Output High Leakage Current
V
OH
 = 5.5V
1
SMBus-COMPATIBLE INTERFACE (SCLK AND SDA)
Logic Input Low Voltage
V
IL
0.8
V
V
CC
 = 3.0V
2.2
Logic Input High Voltage
V
IH
V
CC
 = 5.5V
2.6
V
Input Leakage Current
I
LEAK
V
IN
 = GND or V
CC
-1
+1
Output Low-Sink Current
I
SINK
V
OL
 = 0.6V
6
mA
Input Capacitance
C
IN
5
pF
SMBus-COMPATIBLE TIMING (Note 2)
Serial Clock Frequency
f
SCLK
(Note 3)
100
kHz
Bus Free Time Between STOP and
START Condition
t
BUF
4.7
START Condition Setup Time
4.7
Repeat START Condition Setup
Time
t
SU:STA
90% to 90%
50
ns
START Condition Hold Time
t
HD:STA
10% of SDA to 90% of SCLK
4
STOP Condition Setup Time
t
SU:STO
90% of SCLK to 90% of SDA
4
Clock Low Period
t
LOW
10% to 10%
4.7
Clock High Period
t
HIGH
90% to 90%
4
Data Setup Time
t
HD:DAT
(Note 4)
250
Receive SCLK/SDA Rise Time
t
R
1
Receive SCLK/SDA Fall Time
t
F
300
ns
Pulse Width of Spike Suppressed
t
SP
0
50
ns
SMBus Timeout
t
TIMEOUT
SDA low period for interface reset
25
37
55
ms
Note 1: All parameters tested at a single temperature. Specifications over temperature are guaranteed by design.
Note 2: Timing specifications guaranteed by design.
Note 3: The serial interface resets when SCLK is low for more than t
TIMEOUT
.
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCLKs falling edge.
相关PDF资料
PDF描述
747150-2 CONN D-SUB RECPT STR 9POS PCB AU
MC78L12ACDR2 IC REG LDO 12V .1A 8SOIC
EBC10DRTN CONN EDGECARD 20POS DIP .100 SLD
TAJY227M010RNJ CAP TANT 220UF 10V 20% 2917
EEC10DRTI CONN EDGECARD 20POS DIP .100 SLD
相关代理商/技术参数
参数描述
MAX6692MUA+ 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6692MUA+T 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6692MUA-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6692YMSA+ 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6692YMSA+T 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor