参数资料
型号: MAX6697UP+
厂商: Maxim Integrated
文件页数: 6/18页
文件大小: 234K
描述: IC TEMP MON 7CH PREC 20TSSOP
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 74
功能: 温度监控系统(传感器)
传感器类型: 内部和外部
感应温度: -40°C ~ 125°C,外部传感器
精确度: ±3°C(最小值)
拓扑: ADC,缓冲器,寄存器库
输出类型: I²C?/SMBus?
输出警报:
输出风扇:
电源电压: 3 V ~ 5.5 V
工作温度: -40°C ~ 125°C
安装类型: 表面贴装
封装/外壳: 20-TSSOP(0.173",4.40mm 宽)
供应商设备封装: 20-TSSOP
包装: 管件
Detailed Description
The MAX6697 is a precision multichannel temperature
monitor that features one local and six remote tempera-
ture-sensing channels with a programmable alert
threshold for each temperature channel and a program-
mable overtemperature threshold for channels 1, 4, 5,
and 6 (see Figure 1). Communication with the MAX6697
is achieved through the SMBus serial interface and a
dedicated alert pin. The alarm outputs, OVERT and
ALERT, assert if the software-programmed temperature
thresholds are exceeded. ALERT typically serves as an
interrupt, while OVERT can be connected to a fan, sys-
tem shutdown, or other thermal-management circuitry.
ADC Conversion Sequence
In the default conversion mode, the MAX6697 starts the
conversion sequence by measuring the temperature on
channel 1, followed by 2, 3, local channel, 4, 5, and 6.
The conversion result for each active channel is stored
in the corresponding temperature data register.
In some systems, one of the remote thermal diodes may
be monitoring a location that experiences temperature
changes that occur much more rapidly than in the other
channels. If faster temperature changes must be moni-
tored in one of the temperature channels, the MAX6697
allows channel 1 to be monitored at a faster rate than
the other channels. In this mode (set by writing a 1 to bit
4 of the configuration 1 register), measurements of
channel 1 alternate with measurements of the other
channels. The sequence becomes channel 1, channel
2, channel 1, channel 3, channel 1, etc. Note that the
time required to measure all seven channels is consid-
erably greater in this mode than in the default mode.
Low-Power Standby Mode
Standby mode reduces the supply current to less than
15礎 by disabling the internal ADC. Enter standby by
setting the STOP bit to 1 in the configuration 1 register.
During standby, data is retained in memory, and the
SMBus interface is active and listening for SMBus com-
mands. The timeout is enabled if a start condition is rec-
ognized on SMBus. Activity on the SMBus causes the
supply current to increase. If a standby command is
received while a conversion is in progress, the conver-
sion cycle is interrupted, and the temperature registers
are not updated. The previous data is not changed and
remains available.
7-Channel Precision Temperature Monitor
6  _______________________________________________________________________________________
PIN
NAME
FUNCTION
9
DXP5
Combined Current Source and A/D Positive Input for Channel 5 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to V
CC
 if no
remote diode is used. Place a 2200pF capacitor between DXP5 and DXN5 for noise filtering.
10
DXN5
Cathode Input for Channel 5 Remote Diode. Connect the cathode of the channel 1 remote-diode-
connected transistor to DXN5.
11
DXN6
Cathode Input for Channel 6 Remote Diode. Connect the cathode of the channel 1 remote-diode-
connected transistor to DXN6.
12
DXP6
Combined Current Source and A/D Positive Input for Channel 6 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to V
CC
 if no
remote diode is used. Place a 2200pF capacitor between DXP6 and DXN6 for noise filtering.
13, 14
NC_
No Connect. Must be connected to ground.
15
OVERT
Overtemperature Active-Low, Open-Drain Output. OVERT asserts low when the temperature of
channels 1, 4, 5, and 6 exceeds the programmed threshold limit.
16
V
CC
Supply Voltage Input. Bypass to GND with a 0.1礔 capacitor.
17
ALERT
SMBus Alert (Interrupt), Active-Low, Open-Drain Output. ALERT asserts low when the temperature of
any channel exceeds the programmed ALERT threshold.
18
SMBDATA    SMBus Serial-Data Input/Output. Connect to a pullup resistor.
19
SMBCLK
SMBus Serial-Clock Input. Connect to a pullup resistor.
20
GND
Ground
Pin Description (continued)
相关PDF资料
PDF描述
EBA18DRSN-S288 CONN EDGECARD 36POS .125 EXTEND
VI-2TL-CW-F3 CONVERTER MOD DC/DC 28V 100W
8350-7005 CONN D-SUB RCPT 50POS W/INSERT
TAJD336K016K CAP TANT 33UF 16V 10% 2917
TPSE337M006R0125 CAP TANT 330UF 6.3V 20% 2917
相关代理商/技术参数
参数描述
MAX6697UP+ 功能描述:板上安装温度传感器 7Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6697UP34 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6697UP34+ 功能描述:板上安装温度传感器 7Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6697UP34+T 功能描述:板上安装温度传感器 7Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6697UP34-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor