MAX6701–08/MAX6701A–03A/05A–07A
Low-Voltage, SOT23 P Supervisors with Power-
Fail In/Out, Manual Reset, and Watchdog Timer
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC = +4.25V to +5.5V for L/M versions, VCC = +2.55V to +3.6V for the T/S/R versions, VCC = +2.1V to +2.75V for the Z/Y versions.
TA = -40°C to +125°C, unless otherwise specified. Typical values are at TA = +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VCC ........................................................................-0.3V to +6.0V
Open-Drain RESET, WDO, PFO ...........................-0.3V to +6.0V
Push-Pull RESET, RESET, WDO, PFO ........-0.3V to (VCC + 0.3V)
MR, WDI, PFI, RST_IN1, RST_IN2 ..............-0.3V to (VCC + 0.3V)
Input Current (VCC) .............................................................20mA
Output Current (RESET, RESET, PFO, WDO) .....................20mA
Continuous Power Dissipation (TA = +70°C)
8-Pin SOT23 (derate 8.9mW/°C above +70°C)............714mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
TA = 0
°C to +125°C
1.0
5.5
Operating Voltage Range
VCC
TA = -40
°C to +125°C
1.2
5.5
V
VCC < 5.5V, no load
12
25
VCC < 3.6V, no load
9
20
Supply Current
MR Unconnected
ICC
VCC < 3.6V, no load (MAX6708 only)
6
20
A
TA = -40
°C to +85°C
4.50
4.63
4.75
MAX670_L/MAX670_AL
TA = -40
°C to +125°C
4.47
4.78
TA = -40
°C to +85°C
4.25
4.38
4.50
MAX670_M/MAX670_AM
TA = -40
°C to +125°C
4.22
4.53
TA = -40
°C to +85°C
3.00
3.08
3.15
MAX670_T/MAX670_AT
TA = -40
°C to +125°C
2.97
3.17
TA = -40
°C to +85°C
2.85
2.93
3.00
MAX670_S/MAX670_AS
TA = -40
°C to +125°C
2.83
3.02
TA = -40
°C to +85°C
2.55
2.63
2.70
MAX670_R/MAX670_AR
TA = -40
°C to +125°C
2.53
2.72
TA = -40
°C to +85°C
2.25
2.32
2.38
MAX670_Z/MAX670_AZ
TA = -40
°C to +125°C
2.24
2.40
TA = -40
°C to +85°C
2.12
2.19
2.25
VCC Reset Threshold
(VCC falling)
VTH
MAX670_Y/MAX670_AY
TA = -40
°C to +125°C
2.11
2.27
V
Reset Threshold
Temperature Coefficient
VTH
60
ppm/
°C
VCC to Reset Output Delay
VCC falling at 10mV/s
12
s
TA = -40
°C to +85°C
140
200
280
Reset Timeout Period
tRP
TA = -40
°C to +125°C
120
300
ms
VCC Falling to WDO Delay
MAX6701(A)/MAX6702(A)/MAX6703(A)/MAX6705(A)/
MAX6706(A)/MAX6707(A)
5s
TA = -40
°C to +85°C
602
618
634
PFI, RST_IN1, RST_IN2
Threshold
VCC = 1.8V to 5.5V
TA = -40
°C to +125°C
593
642
mV
PFI Hysteresis
6mV