Appendix A Electrical Characteristics
MC9S12XE-Family Reference Manual Rev. 1.21
Freescale Semiconductor
1231
Because of an order from the United States International Trade Commission, BGA-packaged product lines and partnumbers
indicated here currently are not available from Freescale for import or sale in the United States prior to September 2010
A.4
Voltage Regulator
Device functionality is guaranteed on power down to the LVR assert level.
A.5
Output Loads
Table A-21. Voltage Regulator Electrical Characteristics
Conditions are shown in
Table A-4 unless otherwise noted
Num
C
Characteristic
Symbol
Min
Typical
Max
Unit
1
P
Input Voltages
VVDDR,A
3.13
—
5.5
V
2P
Output Voltage Core
Full Performance Mode
Reduced Power Mode (MCU STOP mode)
Shutdown Mode
VDD
1.72
—
1.84
1.6
—1
1 Voltage Regulator Disabled. High Impedance Output
1.98
—
V
3P
Output Voltage Flash
Full Performance Mode
Reduced Power Mode (MCU STOP mode)
Shutdown Mode
VDDF
2.6
—
2.82
2.2
2.9
—
V
4P
Output Voltage PLL
Full Performance Mode
Reduced Power Mode (MCU STOP mode)
Shutdown Mode
VDDPLL
1.72
—
1.84
1.6
1.98
—
V
5P
Low Voltage Interrupt Asser Level 2
Low Voltage InterruptDeassert Level
2 Monitors VDDA, active only in Full Performance Mode. Indicates I/O & ADC performance degradation due to low supply
voltage.
VLVIA
VLVID
4.04
4.19
4.23
4.38
4.40
4.49
V
6a
P
VDDX Low Voltage Reset Deassert 3
3 Monitors VDDX, active only in Full Performance Mode. MCU is monitored by the POR in RPM (see Figure A-3) VLVRXD
—
3.13
V
6b
D
VDDX Low Voltage Reset assert
3VLVRXA
—
3.02
—
V
6c
P
VDDX Low Voltage Reset assert
3VLVRXA
2.97
—
V
7C
Trimmed API internal clock4
f / fnominal
4 The API Trimming bits must be set that the minimum period equals to 0.2 ms.
dfAPI
- 5%
—
+ 5%
—
8D
The first period after enabling the counter by APIFE
might be reduced by API start up delay
tsdel
—
100
us
9
T
Temperature Sensor Slope
dVTS
5.05
5.25
5.45
mV/oC
10
T
High Temperature Interrupt Assert (VREGHTTR=$88)5
High Temperature Interrupt Deassert
(VREGHTTR=$88)
5 A hysteresis is guaranteed by design
NOTE
The LVR monitors the voltages VDDF and VDDX. If the voltage drops on
these supplies to a level which could prohibit the correct function of the
microcontroller, the LVR triggers.
THTIA
THTID
120
110
132
122
144
134
oC