MCH3322
No.7994-1/4
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
Ordering number : ENN7994
MCH3322
P-Channel Silicon MOSFET
General-Purpose Switching Device
Applications
Features
Low ON-resistance.
Ultrahigh-speed switching.
4V drive.
Specifications
Absolute Maximum Ratings at Ta=25
°C
Parameter
Symbol
Conditions
Ratings
Unit
Drain-to-Source Voltage
VDSS
--100
V
Gate-to-Source Voltage
VGSS
±20
V
Drain Current (DC)
ID
--0.6
A
Drain Current (Pulse)
IDP
PW
≤10s, duty cycle≤1%
--2.4
A
Allowable Power Dissipation
PD
Mounted on a ceramic board (900mm2!0.8mm)
1
W
Channel Temperature
Tch
150
°C
Storage Temperature
Tstg
--55 to +150
°C
Electrical Characteristics at Ta=25
°C
Ratings
Parameter
Symbol
Conditions
min
typ
max
Unit
Drain-to-Source Breakdown Voltage
V(BR)DSS
ID=--1mA, VGS=0
--100
V
Zero-Gate Voltage Drain Current
IDSS
VDS=--100V, VGS=0
--1
A
Gate-to-Source Leakage Current
IGSS
VGS=±16V, VDS=0
±10
A
Cutoff Voltage
VGS(off)
VDS=--10V, ID=--1mA
--1.2
--2.6
V
Forward Transfer Admittance
yfs
VDS=--10V, ID=--300mA
0.5
1.0
S
RDS(on)1
ID=--300mA, VGS=--10V
1.1
1.45
Static Drain-to-Source On-State Resistance
RDS(on)2
ID=--300mA, VGS=--4V
1.2
1.7
Input Capacitance
Ciss
VDS=--20V, f=1MHz
245
pF
Output Capacitance
Coss
VDS=--20V, f=1MHz
16
pF
Reverse Transfer Capacitance
Crss
VDS=--20V, f=1MHz
13
pF
Turn-ON Delay Time
td(on)
See specified Test Circuit.
8.5
ns
Rise Time
tr
See specified Test Circuit.
2.7
ns
Turn-OFF Delay Time
td(off)
See specified Test Circuit.
36
ns
Fall Time
tf
See specified Test Circuit.
16
ns
Marking : JX
Continued on next page.
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft's
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
N2504 TS IM TB-00000251