参数资料
型号: MCP3905L-E/SS
厂商: Microchip Technology
文件页数: 19/32页
文件大小: 0K
描述: IC ENERGY METERING 24SSOP
标准包装: 59
输入阻抗: 390 千欧
测量误差: 0.1%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.85V
电流 - 电源: 2.7mA
电源电压: 4.5 V ~ 5.5 V
测量仪表类型: 单相
工作温度: -40°C ~ 125°C
安装类型: 表面贴装
封装/外壳: 24-SSOP(0.209",5.30mm 宽)
供应商设备封装: 24-SSOP
包装: 管件
MCP3905A/05L/06A
The high-frequency output HF OUT
has lower
4.7.1
MINIMAL OUTPUT FREQUENCY
HF OUT ( Hz ) = ----------------------------------------------------------------
( V REF )
integration times and, thus, higher frequencies. The
output frequency value can be calculated with the
following equation:
EQUATION 4-2: HF OUT FREQUENCY
OUTPUT EQUATION
8.06 × V 0 × V 1 × G × HF C
2
Where:
V 0 is the RMS differential voltage on channel 0
V 1 is the RMS differential voltage on channel 1
G is the PGA gain on channel 0 (current channel)
HF C is the frequency constant selected
V REF is the voltage reference
The constant HF C depends on the F OUT0 and F OUT1
digital settings with the Table 4-4 .
The detailed timings of the output pulses are described
in the Timing Characteristics table (see Section 1.0
“Electrical Characteristics” and Figure 1-1 ).
FOR
NO-LOAD THRESHOLD
The MCP3905A/05L/06A devices also include, on
each output frequency, a no-load threshold circuit that
will eliminate any creep effects in the meter. The
outputs will not show any pulse if the output frequency
falls below the no-load threshold. The minimum output
frequency on F OUT0/1 and HF OUT is equal to 0.0015%
of the maximum output frequency (respectively F C and
HF C ) for each of the F2, F1 and F0 selections (see
Table 4-3 and Table 4-4 ); except when F2, F1,
F0 = 011 . In this last configuration, the no-load
threshold feature is disabled. The selection of F C will
determine the start-up current load. In order to respect
the IEC standards requirements, the meter will have to
be designed to allow start-up currents compatible with
the standards by choosing the FC value matching
these requirements. For additional applications
information on no-load threshold, startup current and
other meter design points, refer to AN994, "IEC
Compliant Active Energy Meter Design Using The
MCP3905/6 ”, (DS00994).
TABLE 4-3:
MCP3905L OUTPUT FREQUENCY SETTINGS
F2
0
0
0
0
1
1
1
1
F1
0
0
1
1
0
0
1
1
F0
0
1
0
1
0
1
0
1
HF C
64X F C
32X F C
16X F C
2048X F C
8X F C
64X F C
32X F C
16X F C
HF C (Hz)
MCLK/2 15
MCLK/2 15
MCLK/2 15
MCLK/2 7
MCLK/2 16
MCLK/2 16
MCLK/2 16
MCLK/2 16
HF C (Hz),
MCLK=3.58 MHz
109.25
109.25
109.25
27968.75
54.62
54.62
54.62
54.62
HF OUT (Hz),
w/ full scale
AC inputs
23.71
23.71
23.71
6070.12
11.85
11.85
11.85
11.85
F C (Hz)
MCLK/2 21
MCLK/2 20
MCLK/2 19
MCLK/2 18
MCLK/2 19
MCLK/2 22
MCLK/2 21
MCLK/2 20
F C (Hz),
MCLK=3.58 MHz
1.71
3.41
6.83
13.66
6.83
0.85
1.71
3.41
TABLE 4-4:
MCP3905A/06A OUTPUT FREQUENCY SETTINGS
F2
0
0
0
0
1
1
F1
0
0
1
1
0
0
F0
0
1
0
1
0
1
HF C
64X F C
32X F C
16X F C
2048X F C
128X F C
64X F C
HF C (Hz)
MCLK/2 15
MCLK/2 15
MCLK/2 15
MCLK/2 7
MCLK/2 14
MCLK/2 14
HF C (Hz),
MCLK=3.58 MHz
109.25
109.25
109.25
27968.75
219.51
219.51
HF OUT (Hz),
w/ full scale
AC inputs
23.71
23.71
23.71
6070.12
47.42
47.42
F C (Hz)
MCLK/2 21
MCLK/2 20
MCLK/2 19
MCLK/2 18
MCLK/2 21
MCLK/2 20
F C (Hz),
MCLK=3.58 MHz
1.71
3.41
6.83
13.66
1.71
3.41
1
1
0
32X F C
MCLK/2
14
219.51
47.42
MCLK/2
19
6.83
1
1
1
16X F C
MCLK/2 14
219.51
47.42
MCLK/2 18
13.66
? 2006-2011 Microchip Technology Inc.
DS22011B-page 19
相关PDF资料
PDF描述
AMM25DRXN CONN EDGECARD 50POS DIP .156 SLD
HMM06DRUS CONN EDGECARD 12POS .156 DIP SLD
GMC60DRTF CONN EDGECARD 120PS DIP .100 SLD
MURF1660CTG DIODE ULT FAST 16A 600V TO-220FP
A7MMB-1510G CABLE D-SUB-AMP15B/AE15G/AMP15B
相关代理商/技术参数
参数描述
MCP3905L-I/SS 功能描述:模数转换器 - ADC Dynamic Range Energy Meter IC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MCP3905LT 制造商:MICROCHIP 制造商全称:Microchip Technology 功能描述:Energy-Metering ICs with Active (Real) Power Pulse Output
MCP3905LT-E/SS 功能描述:模数转换器 - ADC Energy Meter IC Gain Dynamic Range RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MCP3905LT-I/SS 功能描述:模数转换器 - ADC Dynamic Range Energy Meter IC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MCP3905RD-PM1 功能描述:电源管理IC开发工具 Energy Meter Ref Design RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V