Table 54. TSI electrical specifications (continued)
Symbol
Description
Min.
Typ.
Max.
Unit
Notes
CREF
Internal reference capacitor
TBD
1
TBD
pF
VDELTA
Oscillator delta voltage
TBD
600
TBD
mV
IREF
Reference oscillator current source base current
—
1.133
TBD
μA
IELE
Electrode oscillator current source base current
—
1.133
TBD
μA
Pres5
Electrode capacitance measurement precision
—
TBD
%
Pres20
Electrode capacitance measurement precision
—
TBD
%
Pres100
Electrode capacitance measurement precision
—
TBD
%
MaxSens2
0
Maximum sensitivity @ 20 pF electrode
0.003
0.25
—
fF/count
MaxSens Maximum sensitivity
0.003
—
fF/count
Res
Resolution
—
16
bits
TCon20
Response time @ 20 pF
8
15
25
μs
ITSI_RUN
Current added in run mode
—
55
—
μA
ITSI_LP
Low power mode current adder
—
1.3
TBD
μA
1. The TSI module is functional with capacitance values outside this range. However, optimal performance is not guaranteed.
2. CAPTRM=7, DELVOL=7, and fixed external capacitance of 20 pF.
3. CAPTRM=0, DELVOL=2, and fixed external capacitance of 20 pF.
4. CAPTRM=0, EXTCHRG=9, and fixed external capacitance of 20 pF.
5. The programmable current source value is generated by multiplying the SCANC[REFCHRG] value and the base current.
6. Measured with a 5 pF electrode, reference oscillator frequency of 10 MHz, PS = 128, NSCN = 8; Iext = 16.
7. Measured with a 20 pF electrode, reference oscillator frequency of 10 MHz, PS = 128, NSCN = 2; Iext = 16.
8. Measured with a 20 pF electrode, reference oscillator frequency of 10 MHz, PS = 16, NSCN = 3; Iext = 16.
9. Measured with a 20 pF electrode, reference oscillator frequency of ~5 MHz (IREF = 5 μA, REFCHRG = 4), PS = 128,
NSCN = 2; Iext = 16 (EXTCHRG = 15).
10. Typical value depends on the configuration used.
11. Time to do one complete measurement of the electrode. Sensitivity resolution of 0.0133 pF, PS = 0, NSCN = 0, 1
electrode, DELVOL = 2, EXTCHRG = 15.
12. CAPTRM=7, DELVOL=2, REFCHRG=0, EXTCHRG=4, PS=7, NSCN=0F, LPSCNITV=F, LPO is selected (1 kHz), and
fixed external capacitance of 20 pF. Data is captured with an average of 7 periods window.
7 Dimensions
7.1 Obtaining package dimensions
Package dimensions are provided in package drawings.
search for the drawing’s document number:
Dimensions
K52 Sub-Family Data Sheet Data Sheet, Rev. 5, 5/2011.
70
Preliminary
Freescale Semiconductor, Inc.