参数资料
型号: MPL115A2T2
厂商: Freescale Semiconductor
文件页数: 4/16页
文件大小: 0K
描述: IC BAROMETER I2C DGTL MINI 8LGA
标准包装: 5,000
压力类型: 绝对
工作压力: 7.2 PSI ~ 16.6 PSI,50 ~ 115 kPa
输出: 数字
精确度: ±1%
电源电压: 2.375 V ~ 5.5 V
端接类型: PCB
工作温度: -40°C ~ 105°C
封装/外壳: 8-TLGA
出厂设置: *
3
Overview of Functions/Operation
Initial
powerup
Reading
coefficient data
Data conversion
Compensated
pressure reading
Shutdown
Figure 2. Sequence Flow Chart
The MPL115A interfaces to a host (or system) microcontroller in the user ’s application. All communications are via I 2 C. A typical
usage sequence is as follows:
Initial Power-up
All circuit elements are active. I 2 C port pins are high impedance and associated registers are cleared. The device then enters
standby mode.
Reading Coefficient Data
The user then typically accesses the part and reads the coefficient data. The main circuits within the slave device are disabled
during read activity. The coefficients are usually stored in the host microcontoller local memory but can be re-read at any time.
It is not necessary to read the values stored in the host microcontroller multiple times because the coefficients within a device
are constant and do not change. However, note that the coefficients will be different from device to device, and cannot be used
for another part.
Data Conversion
This is the first step that is performed each time a new pressure reading is required which is initiated by the host sending the
CONVERT command. The main system circuits are activated (wake) in response to the command and after the conversion
completes, the result is placed into the Pressure and Temperature ADC output registers.
The conversion completes within the maximum conversion time, tc (see Row 7 , in the Operating Characteristics Table). The
device then enters standby mode.
Compensated Pressure Reading
After the conversion has been given sufficient time to complete, the host microcontroller reads the result from the ADC output
registers and calculates the Compensated Pressure, a barometric/atmospheric pressure value which is compensated for
changes in temperature and pressure sensor linearity. This is done using the coefficient data from the MPL115A and the raw
sampled pressure and temperature ADC output values, in a compensation equation (detailed later). Note that this is an absolute
pressure measurement with a vacuum as a reference.
From this step the host controller may either wait and then return to the Data Conversion step to obtain the next pressure reading
or it may go to the Shutdown step.
MPL115A2
Sensors
4
Freescale Semiconductor, Inc.
相关PDF资料
PDF描述
E-19-U TOUCHSCREEN 19" USB
K-17-C TOUCHSCREEN 17" RS-232 SIDE
MPL115A1T2 IC BAROMETER SPI DGTL MINI 8LGA
K-17-U TOUCHSCREEN 17" USB SIDE MT
K-15-U TOUCHSCREEN 15" USB SIDE MT
相关代理商/技术参数
参数描述
MPL1-1-61-153 制造商:Sensata Technologies 功能描述:MPL1-1-61-153 /Pole # 1 /Prod Family: 0204
MPL-12-12 功能描述:XFRMR 115/230V 5V 270MA 3OUT PCB RoHS:是 类别:变压器 >> 功率 系列:MPL 标准包装:1 系列:260 类型:标准 最大功率:65 VA 主线圈:双 副线圈:三路,中心抽头 在某电流时的串联输出电压:500 VAC @ 85mA,5 VAC @ 2A,6.3 VAC @ 2A 在某电流时的并联输出电压:- 安装类型:底座安装 尺寸/尺寸:102.36mm L x 67.31mm W 高度 - 座高(最大):66.80mm 端接类型:导线引线
MPL-12-15 功能描述:XFRMR 115/230V 5V 270MA 3OUT PCB RoHS:是 类别:变压器 >> 功率 系列:MPL 标准包装:1 系列:260 类型:标准 最大功率:65 VA 主线圈:双 副线圈:三路,中心抽头 在某电流时的串联输出电压:500 VAC @ 85mA,5 VAC @ 2A,6.3 VAC @ 2A 在某电流时的并联输出电压:- 安装类型:底座安装 尺寸/尺寸:102.36mm L x 67.31mm W 高度 - 座高(最大):66.80mm 端接类型:导线引线
MPL135 制造商:DELTA 制造商全称:Delta Electronics, Inc. 功能描述:Big current (55A), Footprint compatible with most standard, Lower temperature rise at big current, Low DCR, Without noise
MPL135-0R4 制造商:DELTA 制造商全称:Delta Electronics, Inc. 功能描述:Big current (55A), Footprint compatible with most standard, Lower temperature rise at big current, Low DCR, Without noise