OUT 2
IN 2
IN 1
IN 4
IN 3
OUT 1
Infrared Coupler LED
Equivalent Circuit Only
Negative True Logic
Red Indicator LED
COM
1 & 2
+Vcc
1 & 2
OUT 4
OUT 3
COM
3 & 4
+Vcc
1
8
9
10
11
13
12
2
3
4
5
6
OUT 2
IN 2
IN 1
IN 4
IN 3
OUT 1
Infrared Coupler LED
Equivalent Circuit Only
Negative True Logic
Red Indicator LED
COM
1 & 2
+Vcc
1 & 2
OUT 4
OUT 3
COM
3 & 4
+Vcc
3 & 4
1
8
9
10
11
13
12
2
3
4
5
6
9002
QUAD Series
Output I/O Modules
For recommended applications and more information contact:
USA:
(800) 8 CRYDOM
(800) 827-9366 (619) 715-7200 fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 e-mail: sales@crydom.com
WEB SITE:
http://www.crydom.com
FASTFAX Product Information:
(888) 267-9191
UK:
(44)1202 812300
fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY:
(49) (0)6874 182580
fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany e-mail: vertrieb@crydom.com
FastFax Document No. 306
SERIES QOUTPUT.070898, PAGE 2 OF 2
1998 CRYDOM CORP Specifications subject to change without notice.
AC Output
(Package Color = Black
)
DC Output
(Package Color = Red
)
WIRING & MECHANICAL DIAGRAMS
GENERAL SPECIFICATIONS
Operating temperature range
–30 to +80°C
Storage temperature range
–40 to +100°C
Isolation
4,000 Vrms
Capacitance input to output
8 pF
Line frequency range
47 to 63 Hz
APPLICATION NOTES
Do not install or remove modules in
live (electrically hot) circuits. High volt-
age may be present.
Input connections are polarized for AC
& DC modules. Output connections are
non-polarized for AC modules.
The controlled voltage on the input
pins (in 1, 2, 3, and 4) cannot exceed 3
Vdc higher than +Vcc. This is a limita-
tion of the reverse breakdown voltage
of the status indicator LEDs.
An externally located commutating
diode must be installed across inductive
loads for DC modules..