(888) IPD-CONVerters q (888) 473-2668 q www.ipdconverters.com
C-20
55
60
65
70
75
80
85
90
95
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY
%
EFF. OBS017ZE
EFF. OBS025ZG
EFF. OBS025ZH
Efficiency vs. Load (48V Input)
65
70
75
80
85
90
95
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY
%
EFF. OBS025YG
EFF. OBS025YH
EFF. OBS025YJ
Efficiency vs. Load (24V Input)
Trim And Enable Pins
Fixed Frequency
1500V Isolation
6-Sided Shielding
DESCRIPTION
FEATURES
OBS SERIES - 25 WATT
OBS single output DC/DC converters provide up to 25
Watts of output power in an industry standard package
and footprint. The OBS units feature excellent efficiency,
six-sided shielding, and fixed switching frequency. With
100°C case operation, the OBS converters are especially
suited to telecom, networking, and industrial
applications. These units are 100% surface-mount
construction and fully compatible with production board
washing processes.
Industry Standard Package
24 and 48V Input
Versions
25W Output Power
100°C Baseplate
Operation
General
Turn-On Time: 24 & 48V
in
10 ms
Remote Shutdown
Positive
Remote Shutdown Reference
V
in
Negative
Switching Frequency
400 kHz
Isolation
Input - Output
1500 VDC
Input - Case (24 V
in units)
500 VDC
Output - Case (48 V
in units)
500 VDC
Temperature Coefficient
0.03%/°C
Case Temperature
Operating Range
-40 to +100°C
Storage Range
-40 to +125°C
Humidity Max., Non-Condensing
95%
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF (Bellcore TR-NWT-000332)
1.8 x 106 hrs
Safety
UL, CUL, TUV
Weight (Approx.)
1.9 oz
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
34 - 75 VDC
Reflected Ripple
25 mA
Input Reverse Voltage Protection
Shunt Diode
Output
Setpoint Accuracy
±1%
Line Regulation V
in
Min - V
in
Max., I
out
Rated
0.2% V
out
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
0.5% V
out
Minimum Output Current
10 % I
out
Rated
Dynamic Regulation, Loadstep
25% I
out
Pk Deviation
4% V
out
Settling Time
500
s
Voltage Trim Range
±10% I
out
Rated
Short Circuit / Overcurrent Protection
Hiccup
Current Limit Threshold Range, % of I
out
Rated
110 - 140%
OVP Trip Range
115 - 140%V
out
Nom.
OVP
Hiccup
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.