型号: OKX2-T/10-D12P-C
厂商: Murata Power Solutions Inc
文件页数: 16/17页
文件大小: 0K
描述: CONVERT DC/DC SIP 50W 0.75-5.5V
产品培训模块: Okami Series
产品目录绘图: OKX(2) Series
特色产品: Okami? Series PoL Converters
标准包装: 114
系列: Okami™ OKX-T/10-D12
类型: 非隔离(POL)
输出数: 1
电压 - 输入(最小): 8.3V
电压 - 输入(最大): 14V
Voltage - Output 1: 0.75 ~ 5.5 V
电流 - 输出(最大): 10A
电源(瓦) - 制造商系列: 50W
安装类型: 通孔
封装/外壳: 11-SIP 模块
尺寸/尺寸: 2.00" L x 0.37" W x 0.50" H(50.8mm x 9.4mm x 12.7mm)
包装: 管件
效率: 94.5%
电源(瓦特)- 最大: 50W
产品目录页面: 2720 (CN2011-ZH PDF)
其它名称: 811-2014-5
OKX T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Minimum Output Loading Requirements
All models regulate within speci?cation and are stable under no load to full
load conditions. Operation under no load might however slightly increase
output ripple and noise.
Thermal Shutdown
To prevent many over temperature problems and damage, these converters
include thermal shutdown circuitry. If environmental conditions cause the
temperature of the DC/DC’s to rise above the Operating Temperature Range
up to the shutdown temperature, an on-board electronic temperature sensor
will power down the unit. When the temperature decreases below the turn-on
threshold, the converter will automatically restart. There is a small amount of
temperature hysteresis to prevent rapid on/off cycling. The temperature sensor
is typically located adjacent to the switching controller, approximately in the
center of the unit. See the Performance and Functional Speci?cations.
CAUTION: If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly test your applica-
tion to avoid unplanned thermal shutdown.
Temperature Derating Curves
The graphs in this data sheet illustrate typical operation under a variety of
conditions. The Derating curves show the maximum continuous ambient air
temperature and decreasing maximum output current which is acceptable
under increasing forced air?ow measured in Linear Feet per Minute (“LFM”).
Note that these are AVERAGE measurements. The converter will accept brief
increases in current or reduced air?ow as long as the average is not exceeded.
Note that the temperatures are of the ambient air?ow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that “natural convection” is de?ned as very ?ow rates which are not
using fan-forced air?ow. Depending on the application, “natural convection” is
usually about 30-65 LFM but is not equal to still air (0 LFM).
Murata Power Solutions makes Characterization measurements in a closed
cycle wind tunnel with calibrated air?ow. We use both thermocouples and an
infrared camera system to observe thermal performance.
CAUTION: If you routinely or accidentally exceed these Derating guidelines,
the converter may have an unplanned Over Temperature shut down. Also, these
graphs are all collected at slightly above Sea Level altitude. Be sure to reduce
the derating for higher density altitude.
Output Fusing
The converter is extensively protected against current, voltage and temperature
extremes. However your output application circuit may need additional protec-
tion. In the extremely unlikely event of output circuit failure, excessive voltage
could be applied to your circuit. Consider using an appropriate fuse in series
with the output.
Output Current Limiting
As soon as the output current increases to approximately 125% to 150% of
mode. The output voltage will decrease proportionally with increases in output
current, thereby maintaining a somewhat constant power output. This is also
commonly referred to as power limiting.
Current limiting inception is de?ned as the point at which full power falls
below the rated tolerance. See the Performance/Functional Speci?cations.
Note particularly that the output current may brie?y rise above its rated value
in normal operation as long as the average output power is not exceeded. This
enhances reliability and continued operation of your application. If the output
current is too high, the converter will enter the short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low (approxi-
mately 98% of nominal output voltage for most models), the PWM controller
will shut down. Following a time-out period, the PWM will restart, causing the
output voltage to begin ramping up to its appropriate value. If the short-circuit
condition persists, another shutdown cycle will initiate. This rapid on/off cycling
is called “hiccup mode”. The hiccup cycling reduces the average output cur-
rent, thereby preventing excessive internal temperatures and/or component
damage. A short circuit can be tolerated inde?nitely.
Remote Sense Input
The Sense input is normally connected at the load for the respective Sense
polarity (+Sense to the +Vout load). Sense inputs compensate for voltage drops
along the output wiring such as moderate IR drops and the current carrying
capacity of PC board etch. This output drop (the difference between Sense and
Vout when measured at the converter) should not exceed 0.5V. Use heavier
connections if this drop is excessive. Sense inputs also improve the stability of
the converter and load system by optimizing the control loop phase margin.
If the Sense function is not used for remote regulation, the user should con-
nect the Sense to their respective Vout at the converter pins.
Sense lines on the PCB should run adjacent to DC signals, preferably
Ground. Any long, distributed wiring and/or signi?cant inductance introduced
into the Sense control loop can adversely affect overall system stability. If in
doubt, test your applications by observing the converter’s output transient
response during step loads. There should not be any appreciable ringing or
oscillation.
You may also adjust the output trim slightly to compensate for voltage loss
in any external ?lter elements. Do not exceed maximum power ratings. Exces-
sive voltage differences between Vout and Sense together with trim adjustment
of the output can cause the overvoltage protection circuit to activate and shut
down the output.
Power derating of the converter is based on the combination of maximum
output current and the highest output voltage at the ouput pins. Therefore the
designer must insure:
(Vout at pins) x (Iout) ≤ (Max. rated output power)
its maximum rated value, the DC/DC converter will enter a current-limiting
www.murata-ps.com/support
MDC_OKX2_T10T16.B05 Page 16 of 17
相关PDF资料
PDF描述
P51-3000-S-T-I36-20MA-000-000 SENSOR 3000PSIS 7/16 4-20 MA
P51-2000-A-E-M12-4.5OVP-000-000 SENSOR 2000PSI 3/8-24UNF .5-4.5V
P51-1000-S-T-D-4.5V-000-000 SENSOR 1000PSI 7/16-20-2B 4.5V
P51-500-S-C-MD-4.5V-000-000 SENSOR 500PSI M12-1.5 6G .5-4.5V
REC5-1209DRW/H4/A/SMD/CTRL CONV DC/DC 5W 9-18VIN +/-09VOUT
相关代理商/技术参数
参数描述
OKX-T/10 制造商:MURATA-PS 制造商全称:Murata Power Solutions Inc. 功能描述:Adjustable DOSA 10/16-Amp SIP DC/DC Converters
OKX-T/10-D12 制造商:Murata Power Solutions 功能描述:- Rail/Tube
OKX-T/10-D12N-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Neg logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX-T/10-D12N-C 制造商:Murata Power Solutions 功能描述:PSU POL SIP 10A 12 VIN NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF; DC / DC Converter Type:DOSA; DC / DC Converter Output Type:Adjustable; Input Voltage DC Min:8.3V; Input Voltage DC Max:14V; No. of Outputs:1; Output Voltage Nom.:750mV to 5.5V; Output Current ;RoHS Compliant: Yes
OKX-T/10-D12P-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Pos logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: