参数资料
型号: OKX2-T/16-D12N-C
厂商: Murata Power Solutions Inc
文件页数: 15/17页
文件大小: 0K
描述: CONVERT DC/DC SIP 80W 0.75-5.5V
产品培训模块: Okami Series
产品目录绘图: OKX(2) Series
特色产品: Okami? Series PoL Converters
标准包装: 114
系列: Okami™ OKX-T/10-D12
类型: 非隔离(POL)
输出数: 1
电压 - 输入(最小): 8.3V
电压 - 输入(最大): 14V
Voltage - Output 1: 0.75 ~ 5.5 V
电流 - 输出(最大): 16A
电源(瓦) - 制造商系列: 80W
安装类型: 通孔
封装/外壳: 11-SIP 模块
尺寸/尺寸: 2.00" L x 0.37" W x 0.50" H(50.8mm x 9.4mm x 12.7mm)
包装: 管件
效率: 94%
电源(瓦特)- 最大: 80W
产品目录页面: 2720 (CN2011-ZH PDF)
其它名称: 811-2017-5
OKX T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
TECHNICAL NOTES
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs of
power conversion components. Fuses should also be used when there is the
possibility of sustained input voltage reversal which is not current-limited. We
recommend a time delay fuse installed in the ungrounded input supply line
with a value which is approximately twice the maximum line current, calcu-
lated at the lowest input voltage. Please refer to the Speci?cations.
The installer must observe all relevant safety standards and regulations. For
safety agency approvals, install the converter in compliance with the end-user
safety standard, i.e. IEC/EN/UL 60950-1.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate properly
until the ramping-up input voltage exceeds and remains at the Start-Up
Threshold Voltage (see Speci?cations). Once operating, converters will not
turn off until the input voltage drops below the Under-Voltage Shutdown Limit.
Subsequent restart will not occur until the input voltage rises again above the
Start-Up Threshold. This built-in hysteresis prevents any unstable on/off opera-
tion at a single input voltage.
Because of the switching nature of DC/DC converters, the input of these
converters must be driven from a source with both low AC impedance and
adequate DC input regulation. Performance will degrade with increasing input
inductance. Excessive input inductance may inhibit operation. The DC input
regulation speci?es that the input voltage, once operating, must never degrade
below the Shut-Down Threshold under all load conditions. Be sure to use
adequate trace sizes and mount components close to the converter.
I/O Filtering, Input Ripple Current and Output Noise
All models in this converter series are tested and speci?ed for input re?ected
ripple current and output noise using designated external input/output compo-
nents, circuits and layout as shown in the ?gures below. External input capaci-
tors (Cin in the ?gure) serve primarily as energy storage elements, minimizing
line voltage variations caused by transient IR drops in the input conductors.
Users should select input capacitors for bulk capacitance (at appropriate
frequencies), low ESR and high RMS ripple current ratings. In the ?gure below,
the Cbus and Lbus components simulate a typical DC voltage bus. Your speci?c
system con?guration may require additional considerations. Please note that
the values of Cin, Lbus and Cbus may vary according to the speci?c converter
model.
TO
V IN
Users should be aware however of input sources near the Under-Voltage
Shutdown whose voltage decays as input current is consumed (such as poorly
regulated capacitor inputs), the converter shuts off and then restarts as the
external capacitor recharges. Such situations could oscillate. To prevent this,
make sure the operating input voltage is well above the UV Shutdown voltage
AT ALL TIMES.
OSCILLOSCOPE
+
+
C BUS
L BUS
CURRENT
PROBE
C IN
+INPUT
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to Vout
Start-Up Time (see Speci?cations) is the time interval between the point when
the ramping input voltage crosses the Start-Up Threshold and the fully loaded
regulated output voltage enters and remains within its speci?ed accuracy band.
Actual measured times will vary with input source impedance, external input
capacitance, input voltage slew rate and ?nal value of the input voltage as it
appears at the converter.
These converters include a soft start circuit to moderate the duty cycle of its
PWM controller at power up, thereby limiting the input inrush current.
The On/Off Remote Control interval from On command to Vout regulated
assumes that the converter already has its input voltage stabilized above the
Start-Up Threshold before the On command. The interval is measured from the
On command until the output enters and remains within its speci?ed accuracy
band. The speci?cation assumes that the output is fully loaded at maximum
rated current. Similar conditions apply to the On to Vout regulated speci?cation
-INPUT
C IN = 2 x 100μF, ESR < 700mΩ @ 100kHz
C BUS = 1000μF, ESR < 100mΩ @ 100kHz
L BUS = 1μH
Figure 2: Measuring Input Ripple Current
In critical applications, output ripple and noise (also referred to as periodic
and random deviations or PARD) may be reduced by adding ?lter elements
such as multiple external capacitors. Be sure to calculate component tempera-
ture rise from re?ected AC current dissipated inside capacitor ESR.
+SENSE
+OUTPUT
such as external load capacitance and soft start circuitry.
C1
C2
SCOPE
R LOAD
Input Source Impedance
These converters will operate to speci?cations without external components,
assuming that the source voltage has very low impedance and reasonable
input voltage regulation. Since real-world voltage sources have ?nite imped-
ance, performance is improved by adding external ?lter components. Some-
times only a small ceramic capacitor is suf?cient. Since it is dif?cult to totally
characterize all applications, some experimentation may be needed. Note that
external input capacitors must accept high speed AC switching currents.
-OUTPUT
C1 = 1μF
C2 = 10μF
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 3: Measuring Output Ripple and Noise (PARD)
www.murata-ps.com/support
MDC_OKX2_T10T16.B05 Page 15 of 17
相关PDF资料
PDF描述
P51-50-A-G-M12-4.5OVP-000-000 SENSOR 50PSI 1/8-27NPT .5-4.5V
NMJ0509SAC CONV DC/DC 1W 5VIN 9V SIP 5.2KV
P51-3000-S-D-MD-4.5V-000-000 SENSOR 3000PSI 7/16-20 UNF 4.5V
3M 8815 SQUARE-2"-100 TAPE ADHESIVE TRANSFER 2" SQ
REC5-0505DRW/H6/A/CTRL CONV DC/DC 5W 4.5-9VIN +/-05VOUT
相关代理商/技术参数
参数描述
OKX-T/10 制造商:MURATA-PS 制造商全称:Murata Power Solutions Inc. 功能描述:Adjustable DOSA 10/16-Amp SIP DC/DC Converters
OKX-T/10-D12 制造商:Murata Power Solutions 功能描述:- Rail/Tube
OKX-T/10-D12N-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Neg logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX-T/10-D12N-C 制造商:Murata Power Solutions 功能描述:PSU POL SIP 10A 12 VIN NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF; DC / DC Converter Type:DOSA; DC / DC Converter Output Type:Adjustable; Input Voltage DC Min:8.3V; Input Voltage DC Max:14V; No. of Outputs:1; Output Voltage Nom.:750mV to 5.5V; Output Current ;RoHS Compliant: Yes
OKX-T/10-D12P-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Pos logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: