参数资料
型号: OKX2-T/16-W5N-C
厂商: Murata Power Solutions Inc
文件页数: 12/13页
文件大小: 0K
描述: CONV DC/DC SIP 52.8W .75-3.6VOUT
产品培训模块: Okami Series
产品目录绘图: OKX(2) Series
特色产品: Okami? Series PoL Converters
标准包装: 114
系列: Okami™ OKX-T/16-W5
类型: 非隔离(POL)
输出数: 1
电压 - 输入(最小): 2.4V
电压 - 输入(最大): 5.5V
Voltage - Output 1: 0.75 ~ 3.63 V
电流 - 输出(最大): 16A
电源(瓦) - 制造商系列: 52W
安装类型: 通孔
封装/外壳: 11-SIP 模块
尺寸/尺寸: 2.00" L x 0.37" W x 0.50" H(50.8mm x 9.4mm x 12.7mm)
包装: 管件
工作温度: -40°C ~ 85°C
效率: 95%
电源(瓦特)- 最大: 52.8W
产品目录页面: 2720 (CN2011-ZH PDF)
其它名称: 811-2151-5
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
will shut down. Following a time-out period, the PWM will restart, causing the
output voltage to begin ramping up to its appropriate value. If the short-circuit
condition persists, another shutdown cycle will initiate. This rapid on/off cycling
+SENSE
+OUTPUT
is called “hiccup mode”. The hiccup cycling reduces the average output cur-
rent, thereby preventing excessive internal temperatures and/or component
damage. A short circuit can be tolerated inde?nitely.
C1
C2
SCOPE
R LOAD
Remote Sense Input
The Sense input is normally connected at the load for the respective Sense
-OUTPUT
C1 = 1μF
C2 = 10μF
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 3: Measuring Output Ripple and Noise (PARD)
CAUTION: If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly test your applica-
tion to avoid unplanned thermal shutdown.
Temperature Derating Curves
The graphs in this data sheet illustrate typical operation under a variety of
conditions. The Derating curves show the maximum continuous ambient air
temperature and decreasing maximum output current which is acceptable
under increasing forced air?ow measured in Linear Feet per Minute (“LFM”).
Note that these are AVERAGE measurements. The converter will accept brief
increases in current or reduced air?ow as long as the average is not exceeded.
Note that the temperatures are of the ambient air?ow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that very low ?ow rates (below about 25 LFM) are similar to “natural
convection”, that is, not using fan-forced air?ow.
Murata Power Solutions makes Characterization measurements in a closed
cycle wind tunnel with calibrated air?ow. We use both thermocouples and an
infrared camera system to observe thermal performance.
CAUTION: If you routinely or accidentally exceed these Derating guidelines,
the converter may have an unplanned Over Temperature shut down. Also, these
graphs are all collected at slightly above Sea Level altitude. Be sure to reduce
the derating for higher density altitude.
Output Current Limiting
Current limiting inception is de?ned as the point at which full power falls
below the rated tolerance. See the Performance/Functional Speci?cations.
Note particularly that the output current may brie?y rise above its rated value
in normal operation as long as the average output power is not exceeded. This
enhances reliability and continued operation of your application. If the output
current is too high, the converter will enter the short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low (approxi-
polarity (+Sense to the +Vout load). The sense input compensates for voltage
drops along the output wiring such as moderate IR drops and the current
carrying capacity of PC board etch. This output drop (the difference between
Sense and Vout when measured at the converter) should not exceed 0.5V. Use
heavier connections if this drop is excessive. The sense input also improves the
stability of the converter and load system by optimizing the control loop phase
margin.
If the Sense function is not used for remote regulation, the user should con-
nect the Sense to their respective Vout at the converter pins.
Sense lines on the PCB should run adjacent to DC signals, preferably
Ground. Any long, distributed wiring and/or signi?cant inductance introduced
into the Sense control loop can adversely affect overall system stability. If in
doubt, test your applications by observing the converter’s output transient
response during step loads. There should not be any appreciable ringing or
oscillation.
Do not exceed maximum power ratings. Excessive voltage differences
between Vout and Sense together with trim adjustment of the output can cause
the overvoltage protection circuit to activate and shut down the output.
Power derating of the converter is based on the combination of maximum
output current and the highest output voltage at the ouput pins. Therefore the
designer must insure:
(Vout at pins) x (Iout) ≤ (Max. rated output power)
Remote On/Off Control
The remote On/Off Control can be ordered with either logic type. Please refer to
the Connection Diagram on page 1 for On/Off connections.
Positive logic models are enabled when the On/Off pin is left open or is
pulled high to +Vin with respect to –Vin. Therefore, the On/Off control can be
disconnected if the converter should always be on. Positive-logic devices are
disabled when the On/Off is grounded or brought to within a low voltage (see
Speci?cations) with respect to –Vin.
Negative logic devices are on (enabled) when the On/Off pin is left open or
brought to within a low voltage (see Speci?cations) with respect to –Vin. The
device is off (disabled) when the On/Off is pulled high (see Speci?cations) with
respect to –Vin.
Dynamic control of the On/Off function must sink appropriate signal current
when brought low and withstand appropriate voltage when brought high.
Be aware too that there is a ?nite time in milliseconds (see Speci?cations)
between the time of On/Off Control activation and stable, regulated output. This
time will vary slightly with output load type and current and input conditions.
mately 98% of nominal output voltage for most models), the PWM controller
www.murata-ps.com/support
MDC_OKX_T10T16-W5 Series.A05 Page 12 of 13
相关PDF资料
PDF描述
OKY-T/3-D12P-C CONV DC/DC 15W 12VIN 3AOUT
OKY-T/3-W5N-C CONV DC/DC 10.9W 5VIN 3AOUT SMD
OKY2-T/16-D12P-C CONV DC/DC 80W 12VIN 16AOUT SMD
OKY2-T/16-W5P-C CONV DC/DC 52.8W 5VIN 16AOUT SMD
OTBH156KNPIR-F CAP FILM 15UF 1.5KVDC QC TERM
相关代理商/技术参数
参数描述
OKX-T/10 制造商:MURATA-PS 制造商全称:Murata Power Solutions Inc. 功能描述:Adjustable DOSA 10/16-Amp SIP DC/DC Converters
OKX-T/10-D12 制造商:Murata Power Solutions 功能描述:- Rail/Tube
OKX-T/10-D12N-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Neg logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX-T/10-D12N-C 制造商:Murata Power Solutions 功能描述:PSU POL SIP 10A 12 VIN NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF 制造商:Murata Power Solutions 功能描述:PSU, POL, SIP, 10A, 12 VIN, NEG ON/OFF; DC / DC Converter Type:DOSA; DC / DC Converter Output Type:Adjustable; Input Voltage DC Min:8.3V; Input Voltage DC Max:14V; No. of Outputs:1; Output Voltage Nom.:750mV to 5.5V; Output Current ;RoHS Compliant: Yes
OKX-T/10-D12P-C 功能描述:DC/DC转换器 12Vin 0.75-5.5Vout 10A 50W Pos logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: