■ RELIABILITY DATA
14. Damp Heat steady state
Specied
No mechanical damage.
Insulation resistance (between 1 and 2) : 20MΩ min.
DC resistance (between 1 and 3)
: 2Ω max.
3Ω max. (FK2125T107AL)
【Test Methods and Remarks】
Temperature : 40±2℃
Humidity
: 90 to 95%RH
Duration
: 500±12 hrs
Recovery
: 2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
15. Loading under Damp Heat
Specied
No mechanical damage.
Insulation resistance (between 1 and 2) : 20MΩ min.
DC resistance (between 1 and 3)
: 2Ω max.
3Ω max. (FK2125T107AL)
【Test Methods and Remarks】
Temperature
: 40±2℃
Humidity
: 90 to 95%RH
Applied voltage : Rated voltage (between 1 and 2)
Applied current : Rated current (between 1 and 3)
Duration
: 500±12 hrs
Recovery
: 2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
16. Loading at High Temperature
Specied
No mechanical damage.
Insulation resistance (between 1 and 2) : 20MΩ min.
DC resistance (between 1 and 3)
: 2Ω max.
3Ω max. (FK2125T107AL)
【Test Methods and Remarks】
Temperature
: 85±2℃
Applied voltage : Rated voltage (between 1 and 2)
Applied current : Rated current (between 1 and 3)
Duration
: 500±12 hrs
Recovery
: 2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
Note on standard condition :
"standard condition" referred to herein is dened as follows :
5 to 35℃ of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20±2℃
of temperature, 60 to 70% relative humidity and 86 to 106kPa of air pressure.
Unless otherwise specied, all the tests are conducted under the "standard condition."
※Circuit diagram
Since neither 1 nor 3 is directional,
either could be served as the IN terminal.