PRODUCT SPECIFICATION
3 (5)
Prepared (also subject responsible if other)
No.
ESKEVIN
3/1301-BMR 640 1211+ Uen
Approved
Checked
Date
Rev
Reference
SEC/D (Julia You)
EZYPING
2007-8-20
B
Operating information continued
Parallel Operation
Paralleling of several converters is easily accomplished by
direct connection of the output voltage terminal pins. The
load regulation characteristic is specifically designed for
optimal paralleling performance. Load sharing between
converters will be within ±10%. It is recommended not to
exceed
P
O = n x 0.9 x POmax, where POmax is the maximum
converter output power and n is the number of paralleled
converters, to prevent overloading any of the converters and
thereby decreasing the reliability performance.
Over Temperature Protection (OTP)
The PKR 2000A Series DC/DC converters include an internal
over temperature shutdown circuit.
When the temperature exceeds 130°C - 150°C on the control
circuit the converter will shut down. The DC/DC converter will
make continuous attempts to start up (non-latching mode)
and resume normal operation automatically when the
temperature has dropped >15°C below the temperature
threshold.
Over Current Protection (OCP)
The converters include current limiting circuitry for protection
at continuous overload.
The output voltage will decrease towards zero for output
currents in excess of max output current (max IO). The
converter will resume normal operation after removal of the
overload. The load distribution should be designed for the
maximum output short circuit current specified.
Synchronization
It is possible to synchronize the switching frequency to an
external symmetrical clock signal. The input can be driven by
a TTL-compatible output and reference to the -input pin 18.
Characteristic
Min
Typ
Max
Unit
High level
2.2
6.5
V
Threshold level*)
1.2
1.7
2.2
V
Low level
0
0.4
V
Sink current
1.5
mA
Sync. Frequency
520
668
kHz
*) Rise time < 10ns
Thermal Consideration
General
The converters are designed to operate in different thermal
environments and sufficient cooling must be provided to
ensure reliable operation.
Cooling is achieved mainly by conduction, from the pins to
the PCB board, and convection, which is dependant on the
airflow across the converter. Increased airflow enhances the
cooling of the converter.
The Output Current Derating graph found in the Output
section for each model provides the available output current
vs. ambient air temperature and air velocity at Vin = 27 V.
The converter is tested on a 254 x 254 mm,
35 μm (1 oz), 8-layer test board mounted vertically in a wind
tunnel with a cross-section of 305 x 305 mm.
Proper cooling of the converter can be verified by measuring
the temperature at position P1. The temperature at these
positions should not exceed the max values provided in the
table below.
Note that the max value is the absolute maximum rating
(non destruction) and that the electrical Output data is
guaranteed up to Tref +95°C.
See Design Note 019 for further information.
Position
Device
Designation
max value
P1
Transformer
Tref
110 C
P2
Mosfet
P3
PCB
P
1
Air Flow
E
PKR 2000A series
DC/DC converters, Input 18-36 V, Output up to 2 A/15 W
EN/LZT 146 352 R2C September 2007
Ericsson Power Modules AB
Technical Specication
19
相关PDF资料
PDF描述
PKR2610ASPBI 1-OUTPUT 6.6 W DC-DC REG PWR SUPPLY MODULE
PKR2113API 1-OUTPUT 12 W DC-DC REG PWR SUPPLY MODULE
PKR2610ASI 1-OUTPUT 6.6 W DC-DC REG PWR SUPPLY MODULE
PKR2221API 2-OUTPUT 15 W DC-DC REG PWR SUPPLY MODULE
PKR2111API 1-OUTPUT 10 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
PKR2111ASIA 制造商:Ericsson 功能描述:
PKR2111ASIB 制造商:Ericsson 功能描述:
PKR2111ASIC 制造商:Ericsson 功能描述:
PKR2113APIA 制造商:Ericsson 功能描述:
PKR2113APIC 制造商:Ericsson 功能描述: