Ericsson Internal
PRODUCT SPECIFICATION
3 (4)
Prepared (also subject responsible if other)
No.
SEC/S David Xie
1/1301-BMR 654 Uen
Approved
Checked
Date
Rev
Reference
EAB/FJB/GMF (Natalie Johansson)
MICNAJO
2009-02-10
C
Safety Specification
General information
Ericsson AB DC/DC converters and DC/DC regulators are
designed in accordance with safety standards
IEC/EN/UL60950, Safety of Information Technology
Equipment
.
IEC/EN/UL60950 contains requirements to prevent injury
or damage due to the following hazards:
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
On-board DC-DC converters are defined as component
power supplies. As components they cannot fully comply
with the provisions of any Safety requirements without
“Conditions of Acceptability”. It is the responsibility of the
installer to ensure that the final product housing these
components complies with the requirements of all
applicable Safety standards and Directives for the final
product.
Component power supplies for general use should comply
with the requirements in IEC60950, EN60950 and
UL60950 “Safety of information technology equipment”.
There are other more product related standards, e.g.
EC61204-7 “Safety standard for power supplies",
IEEE802.3af “Ethernet LAN/MAN Data terminal equipment
power”, and ETS300132-2 “Power supply interface at the
input to telecommunications equipment; part 2: DC”, but all
of these standards are based on IEC/EN/UL60950 with
regards to safety.
Ericsson AB DC/DC converters and DC/DC regulators are
UL60950 recognized and certified in accordance with
EN60950.
The flammability rating for all construction parts of the
products meets requirements for V-0 class material
according to IEC 60695-11-10.
The products should be installed in the end-use equipment,
in accordance with the requirements of the ultimate
application. Normally the output of the DC/DC converter is
considered as SELV (Safety Extra Low Voltage) and the
input source must be isolated by minimum Double or
Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL60950.
Isolated DC/DC converters
It is recommended that a slow blow fuse with a rating twice
the maximum input current per selected product be used at
the input of each DC/DC converter. If an input filter is used
in the circuit the fuse should be placed in front of the input
filter.
In the rare event of a component problem in the input filter
or in the DC/DC converter that imposes a short circuit on
the input source, this fuse will provide the following
functions:
Isolate the faulty DC/DC converter from the input
power source so as not to affect the operation of
other parts of the system.
Protect the distribution wiring from excessive
current and power loss thus preventing hazardous
overheating.
The galvanic isolation is verified in an electric strength test.
The test voltage (Viso) between input and output is
1500 Vdc or 2250 Vdc for 60 seconds (refer to refer to
Absolute maximum ratings).
Leakage current is less than 100 A at nominal input
voltage.
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to Ericsson AB DC/DC converter is 75
Vdc or less, then the output remains SELV (Safety Extra
Low Voltage) under normal and abnormal operating
conditions.
Single fault testing in the input power supply circuit should
be performed with the DC/DC converter connected to
demonstrate that the input voltage does not exceed
75 Vdc.
If the input power source circuit is a DC power system, the
source may be treated as a TNV2 circuit and testing has
demonstrated compliance with SELV limits and isolation
requirements equivalent to Basic Insulation in accordance
with IEC/EN/UL60950.
Non-isolated DC/DC regulators
The input voltage to the DC/DC regulator is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
E
PKU 4000B PI
Intermediate Bus Converters, Input 36-75 V, 20 A / 100 W
EN/LZT 146 376 R2A February 2009
Ericsson AB
Technical Specication
3
相关PDF资料
PDF描述
PKY4616PI 1-OUTPUT 600 W DC-DC REG PWR SUPPLY MODULE
PKY4616PIM 1-OUTPUT 600 W DC-DC REG PWR SUPPLY MODULE
PKY4716PIM 1-OUTPUT 700 W DC-DC REG PWR SUPPLY MODULE
PL-RCP-02-S53-11 FIBER OPTIC RECEIVER, 830-860nm, 2700Mbps
PLL2128X PLL FREQUENCY SYNTHESIZER, 40 MHz
相关代理商/技术参数
参数描述
PKU4101BSI 功能描述:DC/DC转换器 100W 5V OUT 20A 27.9x22.8x8.3 mm RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104BPI 功能描述:DC/DC转换器 120W 12V OUT 10A 27.9x22.8x8.3 mm RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104BSI 功能描述:DC/DC转换器 120W 12V OUT 10A 27.9x22.8x8.3 mm RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104CPI 功能描述:DC/DC转换器 100W 36-75Vin 12V 8.3A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104CSI 功能描述:DC/DC转换器 100W 36-75Vin 12V 8.3A SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: