参数资料
型号: PKU4104BPI/B
厂商: ERICSSON POWER MODULES AB
元件分类: 电源模块
英文描述: 1-OUTPUT 103.75 W DC-DC REG PWR SUPPLY MODULE
封装: ROHS COMPLIANT PACKAGE-5
文件页数: 11/18页
文件大小: 1120K
代理商: PKU4104BPI/B
Ericsson Internal
PRODUCT SPECIFICATION
2 (4)
Prepared (also subject responsible if other)
No.
EMENZHE
1/1301-BMR 654 Uen
Approved
Checked
Date
Rev
Reference
SEC/D (Julia You)
EWEIXIE
2009-07-17
F
Ordering Information
Product program
Output
PKU 4101B PI
5.0 V, 20 A / 100 W
PKU 4104B PI
12.0 V, 8.3 A / 100 W
Product number and Packaging
PKU XXXXX n1 n2 n3 n4
Options
n1
n2
n3
n4
Mounting
x
Remote Control logic
x
Lead length
x
Delivery package information
x
Options
Description
n1
n2
n3
n4
PI
SI
P
LA
LB
/B
/C
Through hole
Surface mount
Negative *
Positive
5.30 mm *
3.69 mm
4.57 mm
Tray
Tape and Reel
Example a through-hole mounted, positive logic, short pin
product with tray packaging would be PKU 4101B PIPLA/B.
* Standard variant (i.e. no option selected).
General Information
Reliability
The Mean Time Between Failure (MTBF) is calculated at
full output power and an operating ambient temperature
(TA) of +40°C, which is a typical condition in Information
and Communication Technology (ICT) equipment. Different
methods could be used to calculate the predicted MTBF
and failure rate which may give different results. Ericsson
Power Modules currently uses two different methods,
Ericsson failure rate data system DependTool and
Telcordia SR332.
Predicted MTBF for the series is:
-
1.6 million hours according to Telcordia SR332, issue
1, Black box technique.
The Ericsson failure rate data system is based on field
tracking data. The data corresponds to actual failure rates
of components used in ICT equipment in temperature
controlled environments (TA = -5...+65°C).
Telcordia SR332 is a commonly used standard method
intended for reliability calculations in ICT equipment. The
parts count procedure used in this method was originally
modelled on the methods from MIL-HDBK-217F, Reliability
Predictions of Electronic Equipment. It assumes that no
reliability data is available on the actual units and devices
for which the predictions are to be made, i.e. all predictions
are based on generic reliability parameters.
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2002/95/EC and have a
maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products include:
-
Lead in high melting temperature type solder (used to
solder the die in semiconductor packages)
-
Lead in glass of electronics components and in
electronic ceramic parts (e.g. fill material in chip
resistors)
-
Lead as an alloying element in copper alloy containing
up to 4% lead by weight (used in connection pins made
of Brass)
Quality Statement
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, 6σ (sigma), and SPC are intensively in use
to boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of our products.
Warranty
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose (including,
but not limited to, use in life support applications, where
malfunctions of product can cause injury to a person’s
health or life).
Ericsson AB 2009
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
E
PKU 4000B PI series
Intermediate Bus Converters
Input 36-75 V, Output up to 20 A / 100 W
EN/LZT 146 376 R3B July 2009
Ericsson AB
Technical Specication
2
相关PDF资料
PDF描述
PKU4101BPILA/C 1-OUTPUT 104 W DC-DC REG PWR SUPPLY MODULE
PKU4101BSIPLB/B 1-OUTPUT 104 W DC-DC REG PWR SUPPLY MODULE
PKU4101BSIPLB/C 1-OUTPUT 104 W DC-DC REG PWR SUPPLY MODULE
PKU4101BPILB/C 1-OUTPUT 104 W DC-DC REG PWR SUPPLY MODULE
PKU4104BPIP/C 1-OUTPUT 103.75 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
PKU4104BSI 功能描述:DC/DC转换器 120W 12V OUT 10A 27.9x22.8x8.3 mm RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104CPI 功能描述:DC/DC转换器 100W 36-75Vin 12V 8.3A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4104CSI 功能描述:DC/DC转换器 100W 36-75Vin 12V 8.3A SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4105CPI 功能描述:DC/DC转换器 100W 36-75Vin 5V 20A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKU4105CPI/B 制造商:Ericsson 功能描述: