Mechanical data
Connections
Pin
Designation
Function
1-2
+Out
Positive output
3-4
GND
Ground
5-6
+In
Positive input
7
Sync In
Synchronization input
8 1)
Sync select
Connect to ground
when used as slave
9
Sync Out
Synchronization output
10
RC
Remote control
11
RC select
Select pin for neg./pos.
logic 2)
12
Vadj
Output voltage adjust
13
+S
Remote sensing
14
NC
Not connected
Product Program
Input Voltage
Output Voltage
Output Current
Output Power
Part No.
1.2 V
12 A
14.4 W
PMA 4118L S/SF
3.0 - 3.6 V
1.5 V
12 A
18.0 W
PMA 4118H S/SF
1.8 V
12 A
21.6 W
PMA 4218G S/SF
2.5 V
12 A
30.0 W
PMA 4119 S/SF
1.2 V
12 A
14.4 W
PMA 5118L S/SF
1.5 V
12 A
18.0 W
PMA 5118H S/SF
4.5 - 5.5 V
1.8 V
12 A
21.6 W
PMA 5218G S/SF
2.5 V
12 A
30.0 W
PMA 5319 S/SF
3.3 V
12 A
39.6 W
PMA 5310 S/SF
1.5 V
16 A
24.0 W
PMA 8218H SF*
9.0 - 16.0 V
3.3 V
16 A
53.0 W
PMA 8510 SF**
5.0 V
16 A
80.0 W
PMA 8811 SF
S = Surface mount
F = Full-lter feature
* adjustable from 1.0V to 2.3V out
** adjustable from 2.3V to 3.6V out
20
8.5
35.2
31.5
14
7
6
Pin #1
ID mark
1
dimensions in mm
1)
Applicable for 4000 and 5000 series.
Not connected (NC) for 8000 series.
2)
Connect to -In for negative logic or leave open for
positive logic on RC pin.
12,3
15,1
2,8
(x3)
(15,4)
2,2
(x7)
(29)
3,5 (x8)
3,5 (x6)
16,25
(36)
1,7
(x8)
2
(x6)
7,7
7,55
Pin 1