MITSUBISHI SEMICONDUCTOR <Intelligent Power Module>
PS21444-E
TRANSFER-MOLD TYPE
INSULATED TYPE
Sep. 2001
2.15
2.25
3.40
1.20
—
0.80
2.60
1.80
1
10
2.85
4.5
0.067
mA
V
Tj = 25
°C
Tj = 125
°C
IC = 15A, Tj = 25
°C
IC = 15A, Tj = 125
°C
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Condition
Symbol
Parameter
Limits
Inverter IGBT part (per 1/6 module)
Inverter FWD part (per 1/6 module)
Case to fin, (per 1 module)
thermal grease applied
Rth(j-c)Q
Rth(j-c)F
Rth(c-f)
Min.
°C/W
THERMAL RESISTANCE
Typ.
Max.
—
Unit
Tj = 25
°C, –IC = 15A, VCIN = 5V
Condition
Symbol
Parameter
Limits
Min.
Typ.
Max.
—
0.10
—
Unit
ELECTRICAL CHARACTERISTICS (Tj = 25
°C, unless otherwise noted)
INVERTER PART
Collector-emitter saturation
voltage
FWD forward voltage
Junction to case thermal
resistance
Contact thermal resistance
VD = VDB = 15V
VCIN = 0V
Switching times
VCC = 300V, VD = VDB = 15V
IC = 15A, Tj = 125
°C, VCIN = 5V 0V
Inductive load (upper-lower arm)
Collector-emitter cut-off
current
VCE = VCES
1.55
1.65
2.50
0.70
0.10
0.40
1.50
0.90
—
V
s
°C/W
Fault output pulse width
ON threshold voltage
OFF threshold voltage
16.5
8.50
1.00
—
1.2
1.8
—
0.55
12.0
12.5
13.0
—
2.0
4.0
15.0
—
0.8
1.2
—
0.5
—
1.8
1.4
3.0
2.5
Trip level
Reset level
Trip level
Reset level
VD
VDB
VFOH
VFOL
VFOsat
VSC(ref)
UVDBt
UVDBr
UVDt
UVDr
tFO
Vth(on)
Vth(off)
tdead
V
ms
V
Limits
CONTROL (PROTECTION) PART
13.5
—
4.9
—
0.8
0.45
10.0
10.5
10.3
10.8
1.0
0.8
2.5
Note 3 : Short circuit protection is functioning only at the low-arms. Please select the value of the external shunt resistor such that the SC trip-
level is less than 25.5 A.
4: Fault signal is output when the low-arms short circuit or control supply under-voltage protective functions operate. The fault output pulse-
width tFO depends on the capacitance value of CFO according to the following approximate equation : CFO = 12.2
10-6 tFO [F].
Total of VP1-VPC, VN1-VNC
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Applied between VP1-VPC, VN1-VNC
Applied between VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Control supply voltage
Condition
Symbol
Parameter
Min.
Typ.
Max.
Unit
VD = VDB = 15V,
VCIN = 5V
VSC = 0V, FO = 10k
5V pull-up
VSC = 1V, FO = 10k
5V pull-up
VSC = 1V, IFO = 15mA
Relates to corresponding input signal for blocking arm
shoot-through.
–20
°C ≤ TC ≤ 100°C
Tj = 25
°C, VD = 15V
(Note 3)
Circuit current
ID
Fault output voltage
Arm shoot-through blocking time
Short circuit trip level
Supply circuit under-voltage
protection
Tj
≤ 125°C
CFO = 22nF
(Note 4)
s
Applied between : UP, VP, WP-VPC, UN, VN, WN-VNC
mA