参数资料
型号: PVC6Q505C01B00
厂商: Murata Electronics North America
文件页数: 49/55页
文件大小: 0K
描述: TRIMMER 5M OHM 0.5W TH
标准包装: 50
系列: PVC6
电阻(欧姆): 5M
功率(瓦特): 0.5W,1/2W
容差: ±10%
温度系数: ±100ppm/°C
匝数: 单路
调节型: 侧面调节
电阻材料: 陶瓷
安装类型: 通孔
端接类型: PC 引脚
包装: 散装
尺寸/尺寸: 方形 - 0.272" L x 0.256" W x 0.315" H(6.90mm x 6.50mm x 8.00mm)
其它名称: 490-2852
! Note ? Please read rating and ! CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
? This catalog has only typical speci?cations. Therefore, please approve our product speci?cations or transact the approval sheet for product speci?cations before ordering.
R50E.pdf
Jul.23,2012
SMD Sealed Type (PVG3/M4A_D01/G5)/Lead Sealed Type (PV32/12/37/36) Speci?cations and Test Methods
Continued from the preceding page.
No.
Item
Test Methods
The trimmer potentiometer should be subjected to Table 4 temperature for 5 cycles. The trimmer potentiometer
should be removed from the chamber, and maintained at a temperature of 25±5°C for 1-2 hours.
6
Temperature Cycle
Sequence 1
Temp. (°C) PV -- series -55±3
2 3 4
+25±2 +125±3 +25±2
Time (min.)
30
5 max.
30
5 max.
Table 4: One cycle of temperature cycle.
1) PV12, PV32, PVM4A --- D01 series
The trimmer potentiometer should be placed in a chamber at a temperature of 40±2°C and a humidity of 90-95%
without loading for 250±8 hours (500±12 hours for PVM4A --- D01 series). The trimmer potentiometer should be
removed from the chamber, and maintained at a temperature of 25±5°C for 5±1/6 hours.
2) PVG3, PVG5, PV36, PV37 series
The trimmer potentiometer should be subjected to the programmed humidity environment for 10 cycle (see Figure 3).
The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for
1.5±1/2 hours.
MIL-STD-202 METHOD 106
70
80-98%RH
80-98%RH
65
INITIAL CONDITIONING
90-98%RH
90-98%RH
90-98%RH
60
IN A DRY OVEN
55
50
45
24 HOURS
HUMIDITY
RATE OF CHANGE OF TEMPERATURE IS UNSPECIFIED.
HOWEVER, SPECIMENS SHOULD NOT BE SUBJECTED
TO RADIANT HEAT FROM CHAMBER-CONDITIONING
40
UNCONTROLLED
PROCESSES
END OF FINAL CYCLE
7
Humidity
35
30
25
20
15
10
INITIAL MEASUREMENTS
AS SPECIFIED IN 3.2
+10°C
-2°C
CIRCULATION OF CONDITIONING AIR SHOULD
BE AT A MINIMUM CUBIC RATE PER MINUTE
EQUIVALENT TO 5 TIMES THE VOLUME OF
THE CHAMBER
MEASUREMENTS AS
SPECIFIED IN 3.6
±2°C AT ALL POINTS WITHIN THE
CHAMBER EXCEPT THE IMMEDIATE
VICINITY OF THE SPECIMENS AND
THE CHAMBER SURFACES
5
0
-5
-10
UNLESS OTHERWISE SPECIFIED
TEMPERATURE TOLERANCE IS,
VOLTAGE APPLIED AS SPECIFIED IN 3.5
STEPS 7a AND 7b PERFORMED DURING ANY
5 OF THE FIRST 9 CYCLES. HUMIDITY
UNCONTROLLED DURING STEPS 7a AND 7b
ONLY
STEP 7a
STEP 7b
PRIOR TO FIRST CYCLE
UNLESS OTHERWISE
STEP 1
STEP 2
STEP 3 STEP 4
STEP 5
STEP 6
STEP 7
SPECIFIED
ONE CYCLE 24 HOURS. REPEAT AS SPECIFIED IN 3.3
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Figure 3
1) PV -- series
8
9
Vibration
Shock
The trimmer potentiometer should be vibrated throughout the frequency range at the 20G level. A complete
frequency range, 10Hz to 2000Hz and back, should be made within 15 minutes for a total of 4 sweeps in each of the
three axis directions for a total of 12 sweeps.
1) PV -- series
The trimmer potentiometer should be shocked at the 100G level and should be subjected to 4 shocks in each of the
three axis directions for a total of 12 shocks.
2) PVM4A --- D01 series
The trimmer potentiometer should be shocked at the 100G level and should be subjected to 3 shocks in each of the
six axis directions for a total of 18 shocks.
Full rated continuous working voltage not exceeding the maximum rated voltage should be applied intermittently
10 Temperature Load Life
11 High Temperature Exposure
between terminal #1 and terminal #3 of the trimmer potentiometer, 1.5 hours on and 0.5 hours off, for a total of
1000±12 hours, at a temperature of 70±2°C (85±2°C for PV37 series). The trimmer potentiometer should be
removed from the chamber, and maintained at a temperature of 25±5°C for 1 to 2 hours.
The trimmer potentiometer should be placed in a chamber at a temperature of 125±3°C 250±8 hours without
loading. The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of
25±5°C for 1 to 2 hours.
The trimmer potentiometer should be placed in a chamber at a temperature of -55±3°C for 1 hours without loading.
12
13
Low Temperature Exposure
(Except for PVM4A --- D01)
Low Temperature Operation
(Only for PVM4A --- D01)
Full rated continuous working voltage not exceeding the maximum rated voltage should be applied for 45 minutes.
The trimmer potentiometer should be removed from the chamber, and maintained at a temperature of 25±5°C for
approximately 24 hours.
The trimmer potentiometer should be placed in a chamber at a temperature of -25±3°C (-55±3°C for
PVM4A --- D01 series) 48±4 hours without loading. The trimmer potentiometer should be removed from the
chamber, and maintained at a temperature of 25±5°C for 1-2 hours.
Continued on the following page.
47
相关PDF资料
PDF描述
QXP2G473KRPT CAP FILM 0.047UF 400VDC RADIAL
GLGA12E7B SWTCH WOBBLE/COIL SPRING SPDT
7116-RC INDUCTOR EMI COMMON MODE 6.8MH
GLAC22B SWITCH TOP PLUNGER SNAP DPDT
PVC6Q504C01B00 TRIMMER 500K OHM 0.5W TH
相关代理商/技术参数
参数描述
PVC7002 制造商:MODELCRAFT 功能描述:MINI BENCH VICE 制造商:MODELCRAFT 功能描述:MINI BENCH VICE; Jaw Width:40mm; Jaw Opening Max:30mm; SVHC:No SVHC (19-Dec-2012) ;RoHS Compliant: NA
PVC7006 制造商:MODELCRAFT 功能描述:HOBBY BENCH VICE 制造商:MODELCRAFT 功能描述:HOBBY BENCH VICE; Jaw Width:60mm; Jaw Opening Max:50mm; SVHC:No SVHC (19-Dec-2012) ;RoHS Compliant: NA
PVC7008 制造商:MODELCRAFT 功能描述:MULTI ANGLE BENCH VICE 制造商:MODELCRAFT 功能描述:TOOL, MULTI ANGLE BENCH VICE, 50MM, 75MM; Jaw Width:75mm; Jaw Opening Max:50mm ;RoHS Compliant: NA
PVC7012 制造商:MODELCRAFT 功能描述:UNIVERSAL SUCTION VICE 制造商:MODELCRAFT 功能描述:UNIVERSAL SUCTION VICE; Jaw Width:70mm; Jaw Opening Max:65mm; SVHC:No SVHC (19-Dec-2012) ;RoHS Compliant: NA
PVC-7-0-CL 制造商:Farnell / Pro-Power 功能描述:SLEEVING INS 7MM BLACK 100M 制造商:pro-power 功能描述:SLEEVING, INS, 7MM, BLACK, 100M 制造商:PRIVATE LABEL 功能描述:SLEEVING, INS, 7MM, BLACK, 100M, Sleeving / Tubing Type:Flexible, Length:100m, S