Q48T25033 DC-DC Converter Data Sheet
36-75 VDC Input; 3.3 VDC @ 25A Output
Characterization
General Information
The converter has been characterized for many operational
aspects, to include thermal derating (maximum load current
as a function of ambient temperature and airflow) for vertical
and horizontal mounting, efficiency, start-up and shutdown
parameters, output ripple and noise, transient response to
load step-change, overload and short circuit.
The following pages contain specific plots or waveforms as-
sociated with the converter. Additional comments for specific
data are provided below.
tween 25°C and 85°C, with airflow rates from 30 to 500 LFM
(0.15 to 2.5 m/s), and vertical and horizontal converter
mounting.
For each set of conditions, the maximum load current was
defined as the lowest of:
(i) The output current at which either any FET junction tem-
perature did not exceed a maximum specified temperature
(120°C) as indicated by the thermographic image, or
(ii) The nominal rating of the converter (25 A).
During normal operation, derating curves with maximum FET
temperature less or equal to 120°C should not be exceeded.
Temperature on the PCB at the thermocouple location
shown in Fig. 27 should not exceed 118°C in order to oper-
ate inside the derating curves.
Test Conditions
All data presented were taken with the converter soldered to
a test board, specifically a 0.060” thick printed wiring board
(PWB) with four layers. The top and bottom layers were not
metalized. The two inner layers, comprising two-ounce cop-
per, were used to provide traces for connectivity to the con-
verter.
The lack of metalization on the outer layers as well as the
limited thermal connection ensured that heat transfer from
the converter to the PWB was minimized. This provides a
worst-case but consistent scenario for thermal derating pur-
poses.
All measurements requiring airflow were made in Power-
One’s vertical and horizontal wind tunnel facilities using In-
frared (IR) thermography and thermocouples for thermome-
try.
Ensuring components on the converter do not exceed their
ratings is important to maintaining high reliability. If one an-
ticipates operating the converter at or close to the maximum
loads specified in the derating curves, it is prudent to check
actual operating temperatures in the application. Thermo-
graphic imaging is preferable; if this capability is not avail-
able, then thermocouples may be used. Power-One recom-
mends the use of AWG #40 gauge thermocouples to ensure
measurement accuracy. Careful routing of the thermocouple
leads will further minimize measurement error. Refer to Fig-
ure 27 for optimum measuring thermocouple location.
Thermal Derating
Load current vs. ambient temperature and airflow rates are
given in Figs. 9-12. Ambient temperature was varied be-
Efficiency
Efficiency vs. load current plots are shown in Figs. 13 and 15
for ambient temperature of 25oC, airflow rate of 300 LFM
(1.5 m/s), both vertical and horizontal orientations, and input
voltages of 36 V, 54 V and 72 V. Also, plots of efficiency vs.
load current, as a function of ambient temperature with Vin =
54 V, airflow rate of 200 LFM (1 m/s) are shown for both a
vertically and horizontally mounted converter in Figs. 14 and
16, respectively.
Start-up
Output voltage waveforms, during the turn-on transient using
the ON/OFF pin for full rated load currents (resistive load)
are shown without and with 10,000 μ F load capacitance in
Figs. 17 and 18, respectively.
Ripple and Noise
Figure 21 shows the output voltage ripple waveform, meas-
ured at full rated load current with a 10 μ F tantalum and 1 μ F
ceramic capacitor across the output. Note that all output
voltage waveforms are measured across a 1 μ F ceramic ca-
pacitor.
The input reflected ripple current waveforms are obtained
using the test setup shown in Fig 22. The corresponding
waveforms are shown in Figs. 23 and 24.
MAR 20, 2003 revised to NOV 20, 2006
Page 8 of 14
www.power-one.com
相关PDF资料
PDF描述
Q48T30015-NBB0 CONV DC-DC 48V IN 1.5V OUT 45W
Q48T30018-NBA0 DC/DC QTR BRICK 54W 1.8V T/H
Q48T30025-NDB0 DC/DC QTR BRICK 75W 2.5V T/H
Q48T30033-NAAC DC/DC QTR BRICK 100W 3.3V T/H
QAK2J335KTP CAP FILM 3.3UF 630VDC AXIAL
相关代理商/技术参数
参数描述
Q48T25033-NBB0G 功能描述:DC/DC转换器 RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
Q48T25033-NBBP 制造商:Power-One 功能描述:DCDC - Bulk
Q48T25033-NBBPG 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
Q48T25033-NBC0G 制造商:Power-One 功能描述:DC/DC PS SGL-OUT 3.3V 25A - Bulk
Q48T25033-NBCP 制造商:Power-One 功能描述:DCDC - Bulk