参数资料
型号: RXEF020-AP
厂商: TE Connectivity
文件页数: 1/1页
文件大小: 0K
描述: POLYSWITCH PTC RESET 0.2A AMMO
产品培训模块: Circuit Protection Products
标准包装: 2,000
系列: PolySwitch®
电流 - 维持(Ih): 200mA
电流 - 跳闸(It): 400mA
电流 - 最大: 40A
电压 - 最大: 72V
R最小/最大: 1.830 ~ 2.750 欧姆
跳闸时间: 2.2s
封装/外壳: 径向,圆盘
包装: 带盒(TB)
其它名称: E87707-000
PolySwitch?
PTC Devices
Overcurrent Protection Device
PRODUCT: RXEF020
DOCUMENT: SCD25215
REV LETTER: H
REV DATE: DECEMBER 06, 2011
PAGE NO.: 1 OF 1
Specification Status: Released
Electrical Rating
Voltage: 72 V max (AC or DC)
Current: 40 A max (AC or DC)
Insulating Material:
Cured, Flame Retardant Epoxy Polymer
meets UL94 V-0 Requirements
Lead Material:
24 AWG Tin Plated Copper Clad Steel
Marking:
Manufacturer’s Mark
X20
and Part Identification
Lot Identification
TABLE I. DIMENSIONS:
A B
C
D
E
MIN MAX MIN MAX
MIN
MAX
MIN
MAX
MIN
MAX
mm:
in*:
-- 7.4 -- 11.7
-- (0.29) -- (0.46)
4.3
(0.17)
5.8
(0.23)
7.6
(0.30)
--
--
--
--
3.0
(0.12)
*Rounded off approximation
TABLE II. PERFORMANCE RATINGS:
I HOLD
RATED
CURRENT
RATINGS
INITIAL
RESISTANCE
TIME TO TRIP
ONE HOUR
POST-TRIP
TRIPPED- STATE
POWER DISSIPATION
CURRENT
VALUES
RESISTANCE
STANDARD
TRIP
AMPERES
AT 20 ° C
HOLD
0.20
AMPERES
AT 20 ° C
HOLD TRIP
0.20 0.40
OHMS
AT 20 ° C
MIN MAX
1.83 2.75
SECONDS AT
20 ° C, 1.0A
MAX
2.2
OHMS
AT 20 ° C
NOMINAL
4.40
WATTS
AT 20 ° C
NOMINAL
0.41
WATTS
AT 20 ° C
MAX
0.64
Agency Recognitions:
Reference Documents:
Precedence:
Effectivity:
CAUTION:
Materials Information
UL, CSA, TUV
PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.
ROHS Compliant
ELV Compliant
Pb-Free
Halogen Free*
HF
* Halogen Free refers to: Br ≤ 900ppm, Cl ≤ 900ppm, Br+Cl ≤ 1500ppm.
? 2005, 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company.
All rights reserved.
相关PDF资料
PDF描述
RXEF020S-2 POLYSWITCH PTC .2A STRAIGHT T/R
RXEF025-AP POLYSWITCH PTC RESET 0.25A AMMO
RXEF030-AP POLYSWITCH PTC RESET 0.3A AMMO
RXEF030S-2 POLYSWITCH PTC .3A STRAIGHT T/R
RXEF040-AP POLYSWITCH PTC RESET 0.4A AMMO
相关代理商/技术参数
参数描述
RXEF020S 功能描述:可复位保险丝 Radial Lead .2A 72V 40A Imax RoHS:否 制造商:Bourns 电流额定值: 电阻:7.5 Ohms 最大直流电压: 保持电流:0.1 A 安装风格:SMD/SMT 端接类型:SMD/SMT 跳闸电流:0.6 A 引线间隔: 系列:MF-PSHT 工作温度范围:- 40 C to + 125 C
RXEF020S-1 功能描述:可复位保险丝 Radial Lead .2A 72V 40A Imax RoHS:否 制造商:Bourns 电流额定值: 电阻:7.5 Ohms 最大直流电压: 保持电流:0.1 A 安装风格:SMD/SMT 端接类型:SMD/SMT 跳闸电流:0.6 A 引线间隔: 系列:MF-PSHT 工作温度范围:- 40 C to + 125 C
RXEF020S-2 功能描述:可复位保险丝 Radial Lead .2A 72V 40A Imax RoHS:否 制造商:Bourns 电流额定值: 电阻:7.5 Ohms 最大直流电压: 保持电流:0.1 A 安装风格:SMD/SMT 端接类型:SMD/SMT 跳闸电流:0.6 A 引线间隔: 系列:MF-PSHT 工作温度范围:- 40 C to + 125 C
RXEF025 功能描述:可复位保险丝 Radial Lead .25A 72V 40A Imax RoHS:否 制造商:Bourns 电流额定值: 电阻:7.5 Ohms 最大直流电压: 保持电流:0.1 A 安装风格:SMD/SMT 端接类型:SMD/SMT 跳闸电流:0.6 A 引线间隔: 系列:MF-PSHT 工作温度范围:- 40 C to + 125 C
RXEF025-1 功能描述:POLYSWITCH PTC RESET 0.25A HOLD RoHS:是 类别:过电压,电流,温度装置 >> PTC 可复位保险丝 系列:PolySwitch® 标准包装:2,000 系列:POLYFUSE® SMD1812 电流 - 维持(Ih):200mA 电流 - 跳闸(It):400mA 电流 - 最大:10A 电压 - 最大:30V R最小/最大:0.800 ~ 5.000 欧姆 跳闸时间:0.02s 封装/外壳:1812(4532 公制),凹陷 包装:带卷 (TR)