The S-8261 series are lithium-ion / lithium polymer rechargeable battery protection ICs incorporating high-accuracy voltage
detection circuit and delay circuit.
The S-8261 series are suitable for protection of single-cell lithium ion/lithium polymer battery packs from overcharge,
overdischarge and overcurrent.
Features
(1)
Internal high accuracy voltage detection circuit
Overcharge detection voltage
3.9 V to 4.4 V (applicable in 5 mV step)
Accuracy:
±25 mV (+25°C) and
±30 mV (5°C to +55°C)
Overcharge hysteresis voltage
0.1 V to 0.4 V
*1
Accuracy:
±25 mV
The overcharge hysteresis voltage can be selected from the range 0.1 V to 0.4 V in 50 mV step.
Overdischarge detection voltage
2.0 V to 3.0 V (applicable in 10 mV step)
Accuracy:
±50 mV
Overdischarge hysteresis voltage
0.0 V to 0.7 V
*2
Accuracy:
±50 mV
The overdischarge hysteresis voltage can be selected from the range 0.0 V to 0.7 V in 100 mV step.
Overcurrent 1 detection voltage
0.05 V to 0.3 V (applicable in 10 mV step) Accuracy:
±15 mV
Overcurrent 2 detection voltage
0.5 V (fixed)
Accuracy:
±100 mV
(2)
High voltage device is used for charger connection pins (VM and CO pins: absolute maximum rating
= 28 V).
(3)
Delay times (overcharge: tCU, overdischarge: tDL, overcurrent 1: tlOV1, overcurrent 2: tlOV2) are generated by an
internal circuit. No external capacitor is necessary.
Accuracy:
±20%
(4)
Three-step overcurrent detection circuit is included (overcurrent 1, overcurrent 2 and load short-circuiting).
(5)
0 V battery charge function “Available” / “Unavailable” are selectable.
(6)
Power-down function “Yes” / “No” are selectable.
(7)
Charger detection function and abnormal charge current detection function
The overdischarge hysteresis is released by detecting negative voltage at the VM pin (0.7 V typ.) (Charger
detection function).
When the output voltage of the DO pin is high and the voltage at the VM pin is equal to or lower than the charger
detection voltage (
0.7 V typ.), the output voltage of the CO pin goes low (Abnormal charge current detection
function).
(8)
Low current consumption
Operation mode
3.5
μA typ., 7.0 μA max.
Power-down mode
0.1
μA max.
(9)
Wide operating temperature range
40°C to +85°C
(10) Lead-free, Sn 100%, halogen-free
*3
*1. Overcharge release voltage
= Overcharge detection voltage Overcharge hysteresis voltage (where overcharge
release voltage
< 3.8 V is prohibited.)
*2. Overdischarge release voltage
= Overdischarge detection voltage + Overdischarge hysteresis voltage (where
overdischarge release voltage
> 3.4 V is prohibited.)
*3. Refer to “
Product Name Structure” for details.
Applications
Lithium-ion rechargeable battery packs
Lithium polymer rechargeable battery packs
Package