参数资料
型号: SCC2691AE1A28,602
厂商: NXP Semiconductors
文件页数: 23/25页
文件大小: 0K
描述: IC UART SINGLE 28-PLCC
产品培训模块: Stand-Alone UARTs
标准包装: 37
特点: 故障启动位检测
通道数: 1,UART
FIFO's: 3 位
电源电压: 5V
带自动流量控制功能:
带故障启动位检测功能:
带CMOS:
安装类型: 表面贴装
封装/外壳: 28-LCC(J 形引线)
供应商设备封装: 28-PLCC(11.51x11.51)
包装: 管件
其它名称: 568-1214-5
935026970602
SCC2691AE1A28
Philips Semiconductors
Product data sheet
SCC2691
Universal asynchronous receiver/transmitter (UART)
2006 Aug 04
7
BLOCK DIAGRAM
As shown in the block diagram, the UART consists of: data bus buffer,
interrupt control, operation control, timing, receiver and transmitter.
Data Bus Buffer
The data bus buffer provides the interface between the external and
internal data busses. It is controlled by the operation control block to
allow read and write operations to take place between the controlling
CPU and UART.
Interrupt Control
A single interrupt output (INTRN) is provided which may be asserted
upon occurrence of any of the following internal events:
Transmit holding register ready
Transmit shift register empty
Receive holding register ready or FIFO full
Change in break received status
Counter reached terminal count
Change in MPI input
Assertion of MPI input
Associated with the interrupt system are the interrupt mask register
(IMR) and the interrupt status register (ISR). The IMR can be
programmed to select only certain of the above conditions to cause
INTRN to be asserted. The ISR can be read by the CPU to
determine all currently active interrupting conditions. However, the
bits of the ISR are not masked by the IMR.
Operation Control
The operation control logic receives operation commands from the
CPU and generates appropriate signals to internal sections to
control device operation. It contains address decoding and read and
write circuits to permit communications with the microprocessor via
the data bus buffer. The functions performed by the CPU read and
write operations are shown in Table 1.
Table 1.
Register Addressing
A2
A1
A0
READ
(RDN = 0)
WRITE
(WRN = 0)
0
MR1, MR2
0
1
SR
CSR
0
1
0
BRG Test
CR
0
1
RHR
THR
1
0
1X/16X Test
ACR
1
0
1
ISR
IMR
1
0
CTU
CTUR
1
CTL
CTLR
NOTE;
*Reserved registers should never be read during operation since
they are reserved for internal diagnostics.
ACR = Auxiliary control register
CR = Command register
CSR = Clock select register
CTL = Counter/timer lower output register
CTLR = Counter/timer lower preset register
CTU = Counter/timer upper output register
CTUR = Counter/timer upper preset register
MR = Mode register A
SR = Status register
THR = Tx holding register
* See Table 6 for BRG Test frequencies in this data sheet, and
“Extended baud rates for SCN2681, SCN68681, SCC2691,
SCC2692, SCC68681 and SCC2698B” Philips Semiconductors ICs
for Data Communications, IC-19, 1994.
Mode registers 1 and 2 are accessed via an auxiliary pointer. The
pointer is set to MR1 by RESET or by issuing a reset pointer
command via the command register. Any read or write of the mode
register while the pointer is at MR1 switches the pointer to MR2. the
pointer then remains at MR2 so that subsequent accesses are to
MR2, unless the pointer is reset to MR1 as described above.
Timing Circuits
The timing block consists of a crystal oscillator, a baud rate
generator, a programmable 16-bit counter/timer, and two clock
selectors.
The crystal oscillator operates directly from a 3.6864MHz crystal
connected across the X1/ CLK and X2 inputs with a minimum of
external components. If an external clock of the appropriate
frequency is available, it may be connected to X1/CLK. If an external
clock is used instead of a crystal, X1/CLK is driven using a
configuration similar to the one in Figure 7. In this case, the input
high-voltage must be capable of attaining the voltage specified in the
DC Electrical Characteristics. The clock serves as the basic timing
reference for the baud rate generator (BRG), the counter/timer, and
other internal circuits. A clock frequency, within the limits specified in
the electrical specifications, must be supplied if the internal BRG is
not used.
The baud rate generator operates from the oscillator or external
clock input and is capable of generating 18 commonly used data
communications baud rates ranging from 50 to 38.4K baud. Thirteen
of these are available simultaneously for use by the receiver and
transmitter. Eight are fixed, and one of two sets of five can be
selected by programming ACR[7]. The clock outputs from the BRG
are at 16X the actual baud rate. The counter/timer can be used as a
timer to produce a 16X clock for any other baud rate by counting
down the crystal clock or an external clock. The clock selectors
allow the independent selection by the receiver and transmitter of
any of these baud rates or an external timing signal.
Counter/Timer (C/T)
The C/T operation is programmed by ACR[6:4]. One of eight timing
sources can be used as the input to the C/T. The output of the C/T is
available to the clock selectors and can be programmed by
ACR[2:0} to be output on the MPO pin.
In the timer mode, the C/T generates a square wave whose period is
twice the number of clock periods loaded into the C/T upper and
lower registers. The counter ready bit in the ISR is set once each
cycle of the square wave. If the value in CTUR or CTLR is changed,
the current half-period will not be affected, but subsequent
half-periods will be affected. In this mode the C/T runs continuously
and does not recognize the stop counter command (the command
only resets the counter ready bit in the ISR). Receipt of a start C/T
command causes the counter to terminate the current timing cycle
and to begin a new cycle using the values in CTUR and CTLR.
In the counter mode, the C/T counts down the number of pulses
loaded into CTUR and CTLR. Counting begins upon receipt of a
start C/T command. Upon reaching terminal count, the counter
ready bit in the ISR is set. The counter continues counting past the
terminal count until stopped by the CPU. If MPO is programmed to
be the output of the C/T, the output remains high until terminal count
is reached, at which time it goes low. The output returns to the high
state and the counter ready bit is cleared when the counter is
stopped by a stop counter command. the CPU may change the
相关PDF资料
PDF描述
VI-26Z-IW CONVERTER MOD DC/DC 2V 40W
VE-BTN-IX-F1 CONVERTER MOD DC/DC 18.5V 75W
MS27484E8F98S CONN PLUG 3POS STRAIGHT W/SCKT
VE-BTN-IW-F4 CONVERTER MOD DC/DC 18.5V 100W
VI-26T-IY CONVERTER MOD DC/DC 6.5V 50W
相关代理商/技术参数
参数描述
SCC2691AE1A28-T 功能描述:UART 接口集成电路 5V INDSTRL UART 1 C RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
SCC2691AE1N24 制造商:PHILIPS 制造商全称:NXP Semiconductors 功能描述:Universal asynchronous receiver/transmitter UART
SCC2691AE1N24,129 功能描述:UART 接口集成电路 5V INDSTRL UART 1 C RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
SCC2691AE1N24,602 功能描述:UART 接口集成电路 1CH. 5V IND. UART RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
SCC2691AE1N24-S 功能描述:UART 接口集成电路 5V INDSTRL UART 1 C RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel