参数资料
型号: SCUBT-200/A
厂商: Red Lion Controls
文件页数: 3/4页
文件大小: 0K
描述: TIME/COUNTER 5 1/2 DIGIT
标准包装: 1
系列: SUB-CUB
计数速率: 500kHz
数字/字母数: 5
输入类型: 电压
电源电压: 2.5 V ~ 5.5 V
显示器类型: LCD 无背光
其它名称: RLC07
SCUBT
SCUBT-200
MODE SELECTION
The SUB-CUB-T can be programmed to operate in one of four timing modes
or in one of eight counting modes. Mode selection is accomplished by
connecting the four CONTROL inputs (C0, C1, C2, & C3) to the appropriate
voltage level (Where 0 = V SS , and 1 = V DD ) . Refer to the chart below.
DECIMAL POINT SELECTION
The SUB-CUB-T is capable of displaying a decimal point in either the first
position or the second position, as well as no decimal point. If selected, the
decimal point will flash at a 1 Hz rate (along with the LCD COLON) in all timer
modes while the SIG input is activated. When the SIG input is de-activated, the
MODE
0
C3
0
C2
0
C1
0
C0
0
MODE DESRIPTION
Hours Timer
selected decimal point will remain “ON”. Use the following table to determine
the proper connections for the desired decimal point position.
1
2
3
4
5
0
0
0
0
0
0
0
0
1
1
0
1
1
0
0
1
0
1
0
1
0.1 Hours Timer
0.01 Hours Timer
0.1 Minutes Timer
X1 Counter w/Debounce
X1 Counter w/o Debounce
DISPLAY
00000
0000.0
000.00
DP2
CONNECT TO BP
CONNECT TO BP
CONNECT TO WINK
DP1
CONNECT TO BP
CONNECT TO WINK
CONNECT TO BP
6
7
8
9
0
0
1
1
1
1
0
0
1
1
0
0
0
1
0
1
÷10 Counter w/Debounce
÷10 Counter w/o Debounce
÷100 Counter w/Debounce
÷100 Counter w/o Debounce
10
11
12
13
14
15
1
1
1
1
1
1
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
÷1000 Counter w/Debounce
÷1000 Counter w/o Debounce
Factory Test Modes
Reset Mode *
TYPICAL APPLICATION
AC MOTOR RUN TIME
An equipment manufacturer is interested in knowing the total run time of
a motor for service purposes. The timer must be capable of operating
* The reset mode (Mode 15) can be used to reset the Timer/Counter to 0.
The SUB-CUB-T should NOT be left in this mode for longer than a few
seconds; otherwise damage to the LCD may result.
TIMER OPERATION
The SUB-CUB-T can be programmed to operate in one of four time intervals
directly from the power line and must be able to record time in 1/10 hour
increments.
The SUB-CUB-T can be used in this application. Since the SUB-CUB-
T can accept either an AC or DC signal input, no blocking diodes are
required. To protect the SIG input from damage due to overvoltage, R1 is
used to limit the input current to less than 1 mA.
(See Mode Selection Chart) . When operated as a timer, the SUB-CUB-T
display will show “00000” when initially reset. The SUB-CUB-T will start to
accumulate time at the selected time interval when the SIG input is connected
to V DD . The COLON LCD segments will flash at a 1 Hz rate for the period of
time that SIG is held high. When the LCD display reaches 99999, the display
will increment to 100000. A maximum display of 199999 can be displayed. On
the next time interval, the display will wrap around to 00000.
COUNTER OPERATION
The SUB-CUB-T can be programmed to operate in one of eight count
modes; four modes with debounce and four modes without debounce (See
Mode Selection Chart) . When operated as a counter, the SUB-CUB-T will reset
to 00000 and will increment on the rising edge of the SIG input. A maximum
of 199999 counts can be displayed before the SUB-CUB-T wraps around to
00000.
TYPICAL APPLICATION
PORTABLE PARTICAL COUNTER WITH ELAPSED TIME INDICATOR
An equipment builder has been contracted to supply a hand-held device
which is capable of measuring and recording both partical counts and sample
time. The partical counts should be measured in units of 1,000. The counter
should be able to accept a signal rate of up to 1,000 counts per second. An
elapsed time indicator measuring time in 1/100 of hours is needed to report the
length of sampling time. A RUN switch should enable both the counter and
the timer. A common RESET switch should clear both units. Both devices
must be able to operate from a 4.5 VDC battery pack and must consume a
minimum of power to prolong battery life.
The SUB-CUB-T can be used to satisfy both requirements. The
COUNTER should be operated in the “÷1000 Count w/o Debounce” mode
(Mode 11). The 0 to 4.5 VDC output pulse of the Partical Sensor can be
3
connected directly to the counter input. Both DP1 and DP2 are connected to
the BP output to disable the decimal points. The TIMER should be operated
in the “0.01 Hours” mode (Mode 2). The SIG input is enabled when the RUN
switch is closed. The 100 K pull-down resistor will disable the SIG input
when the RUN switch is opened. The value of this resistor is kept high to
reduce power consumption. DP2 is enabled by connecting it to the WINK
output. DP1 is disabled by connecting it to the BP output. Both the
COUNTER and the TIMER are cleared by pressing the RESET button. This
will place the SUB-CUB-T’s in the RESET mode (Mode 15). When the
RESET switch is opened, both units will return to their normal modes of
operation.
相关PDF资料
PDF描述
SHE-2500 XFRMR 100-230V/115-230V 2.5KVA
SK4700900 SMT FILTER SAMPLE KIT
SLT-1000 XFRMR 277V/115-125V 1000VA
SP-128 INDUCTOR AUDIO 0.1 HENRY
SP-13 TRANSF 25K CT 20K CT/1K 800CT AU
相关代理商/技术参数
参数描述
SCUDPHBRBEIGE 制造商:FibreFab 功能描述:
SCUDZR02 制造商:FibreFab 功能描述:
SCUPC-900-COL1-4 制造商:3M Electronic Products Division 功能描述:SCUPC-900-COL1-4 SCUPC 900UM P 80611320591
SCUPC-900-COL9-12 制造商:3M Electronic Products Division 功能描述:SCUPC-900-COL9-12 SCUPC 900UM 80611320617
SCUPCI 制造商:OMRON INDUSTRIAL AUTOMATION 功能描述:SCSI CARD(I/O DATA TYPE-RE:RTS