Luton Road, Dunstable, Bedfordshire LU5 4LJ England
Telephone: 01582 662241 Fax: 01582 600767
E-mail: info@erg.co.uk http://www.erg.co.uk
SLDS
-
014
style
Number of
Part Nos
Length
s.p.s.t
SDLS-plus
mm
suffix
max
1
1-014
3.1
2
2-014
5.0
4
4-014
10.1
6
6-014
15.0
Low profile ON/OFF s.p.s.t.
SDLS 014 series
at 20C 70% R.H.
Contact Ratings: Non Switching: 100Vac, 5A
Switching: 1V to 100V, 1A to 1A up to 10VA.
Initial Contact Resistance: (at 10mV, 10mA max.)
Typical: 10m
. Max. 20m.
Insulation Resistance: (at 500Vdc min.) 10,000M
.
Life: For the first 1000 closures the standard deviation of the
change in resistance from the mean is usually less than 1m
.
Mechanical wear out of the sliding actuator is usually observed
after 10,000 operations.
Dielectric Strength: 1 minute: 500Vrms 50Hz.
Capacitance Between Open Contacts: < 1pf at 1KHz.
Temperature: Operating range for continuous electrical use
and manual operation is restricted to -55C to +100C for
standard products.
Humidity: BS 2011 Test Ca: 56 days.
Principal Electrical and Performance Data
This leaflet is believed to contain the best information available at the time of printing, but is subject to change without notice. Performance figures, where quoted, are actually estimates based on
our experience or that of our customers or statutory authorities. In common with all components reliability varies with many factors, and users are invited to contact us in appropriate cases so that
where relevant information is available it may be considered by the user. All supplies are subject to the Company’s standard conditions of sale which are available on request.
Bump: BS 2011 Test Eb: No contact interruptions > 1s during
4000 bumps at 390m/s2 (40g).
Acceleration: BS 2011 Test Ga: No contact interruptions > 1s
during test at 980 m/s2 (100g).
Vibration: BS 2011 Test Fc: 10 to 2000Hz. No contact
interruptions > 1s during test at 147 m/s2 (15g) or 1.0mm
displacement amplitude.
Shock: BS 2011 Test Ea: 980 m/s2 (100g). No contact
interruptions > 1s during test.
Soldering: Solderability: < 2 seconds to wet at 235C as per
IEC 68 and BS 2011 Test T, solder bath method.
Resistance to soldering heat as per IEC 68 and BS 2011 10
seconds satisfactory at 260C when mounted on 1.5mrn PCB.
Please note: BS 2011 is now superseded by BS EN 60068.