Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
200042 Rev. B Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice. October 26, 2004
1
DATA SHEET
Surface Mount General Purpose Schottky Diodes
Features
●
Tight parameter distribution
●
Available as singles and pairs
●
100% DC tested
●
Designed for high volume commercial applications
●
Available in tape and reel packaging
Description
This series of 8, 20 and 70 V rated low cost plastic packaged
Schottky diodes are designed for general purpose use in RF applica-
tions as detectors, mixers and switches and in digital pulse forming
applications. All diodes are fully characterized including SPICE model
parameters and deliver tight parameter distribution, minimizing per-
formance variability. They are available in SC-70, SC-79, SOD-323,
SOT-23, SOT-143 and LGA packages. Wiring configurations include
singles, common cathode, series pairs and unconnected pairs.
Available in tape and reel for pick and place manufacturing.
Characteristic
Value
Reverse voltage (VR)
Rated VB
Forward current - steady state (IF)
50 mA
Forward current - 1 ms pulse (IF)1A
Power dissipation (PD)
75 mW
Storage temperature (TST)
-65 °C to +150 °C
Operating temperature (TOP)
-65 °C to +150 °C
Junction temperature (TJ)
150 °C
Soldering temperature
260 °C for 5 seconds
ESD human body model
Class 1B
Absolute Maximum Ratings
Skyworks offers lead (Pb)-free “environmentally
friendly” packaging that is RoHS compliant
(European Parliament for the Restriction of
Hazardous Substances).
NEW
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, Electrostatic Discharge (ESD) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.