47
SMSASERIES
5 WATT
DC/DC C
ONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, radiation level O, unless otherwise specified.
Notes
1. Up to 4 watts (80% of full power) is available from either output providing the
opposite output is carrying 20% of total power.
2. Shows regulation effect on the minus output during the defined cross loading
conditions, with 80% and 20% referring to the total output power of the
converter. See Figures 15 and 16.
3. Indefinite short circuit protection not guaranteed above 125°C (case).
4. Recovery time is measured from application of the transient to point at which
V
OUT
is within 1% of V
OUT
at final value.
5. Guaranteed but not tested.
DUAL OUTPUT MODELS
SMSA 2805D
SMSA2812D
SMSA2815D
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
OUTPUT VOLTAGE
+V
OUT
–V
OUT
4.95
5.00
5.05
11.88
12.00
12.12
14.85
15.00
15.15
VDC
4.9
5.0
5.1
11.76
12.00
12.24
14.70
15.00
15.30
OUTPUT CURRENT
1
V
IN
= 16 to 40 VDC
Tc = –55°C to +125°C
—
±500
800
—
±208
333
—
±167
267
mA
OUTPUT POWER
1
V
IN
= 16 to 40 VDC
Tc = –55°C to +125°C
—
—
5
—
—
5
—
—
5
W
OUTPUT RIPPLE VOLT.
10 kHz - 2 MHz
—
—
300
—
80
300
—
120
300
mV p-p
LINE REGULATION
Vin = 16 to 40 VDC
Tc = –55°C to +125°C
+V
OUT
–V
OUT
—
20
100
—
20
100
—
10
50
mV
—
40
200
—
40
200
—
40
180
LOAD REGULATION
NO LOAD TO FULL
Tc = –55°C to +125°C
+V
OUT
–V
OUT
—
10
120
—
10
120
—
10
50
mV
—
100
400
—
100
400
—
50
200
CROSS REGULATION
2
+P
O
= 30 - 70 %, –P
O
=70 - 30%
–P
O
= 30 - 70 %, +P
O
= 70 - 30%
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
5
50 msec
NO LOAD
—
5
8
—
3.7
6
—
3
6
%
INPUT VOLTAGE
16
28
40
16
28
40
16
28
40
VDC
—
—
—
30
50
50
—
—
—
40
50
63
—
—
—
38
50
60
V
INPUT CURRENT
FULL LOAD
INHIBITED
10 kHz TO 10 MHz
Tc = –55°C to +125°C
—
—
—
—
65
248
3
50
60
70
—
5
200
300
—
—
—
—
—
67
235
3
50
60
73
—
5
200
300
—
—
—
—
—
68
235
3
50
60
73
—
5
200
300
—
mA
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
3, 4
mA p-p
%
POWER DISSIPATION
SHORT CIRCUIT
RECOVERY
50% - 100% - 50% BALANCED
TRANSIENT
RECOVERY
4, 5
—
—
1.3
—
2.1
50
—
—
1.3
1
1.7
30
—
—
1.3
1
1.6
50
W
ms
STEP LOAD
RESPONSE
—
±200
±550
—
±200
±550
—
±220
±600
mV
—
200
500
—
200
500
—
200
500
μs
STEP LINE RESP.
4, 5
TRANSIENT
16 TO 40 VDC
40 TO 16 VDC
—
—
±200
±200
±500
±500
—
—
±200
±200
±500
±500
—
—
±600
±600
±1500
±1500
mV pk
RECOVERY
16 TO 40 VDC
40 TO 16 VDC
DELAY
OVERSHOOT
5
—
—
—
—
300
800
10
0
750
2000
30
500
—
—
—
—
300
800
10
0
750
2000
30
500
—
—
—
—
500
500
10
0
1200
1200
25
500
μs
START-UP
ms
mV pk