SN74LVC158A
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS342D – MARCH 1994 – REVISED JANUARY 1997
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Output voltage range, V
O
(see Notes 1 and 2)
Input clamp current, I
IK
(V
I
< 0)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
Continuous output current, I
O
(V
O
= 0 to V
CC
)
Continuous current through V
CC
or GND
Package thermal impedance,
θ
JA
(see Note 3): D package
–0.5 V to 6.5 V
–0.5 V to 6.5 V
–0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DB package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The value of VCC is provided in the recommended operating conditions table.
3. The package thermal impedance is calculated in accordance with EIA/JEDEC Std JESD51.
–50 mA
±
50 mA
±
50 mA
±
100 mA
113
°
C/W
131
°
C/W
149
°
C/W
–65
°
C to 150
°
C
recommended operating conditions (see Note 4)
MIN
MAX
3.6
UNIT
VCC
Supply voltage
Operating
2
V
Data retention only
1.5
VIH
VIL
VI
VO
High-level input voltage
VCC = 2.7 V to 3.6 V
VCC = 2.7 V to 3.6 V
2
V
Low-level input voltage
0.8
V
Input voltage
0
5.5
V
Output voltage
0
VCC
–12
V
IOH
High-level output current
VCC = 2.7 V
VCC = 3 V
VCC = 2.7 V
VCC = 3 V
mA
–24
IOL
Low-level output current
12
mA
24
t/
v
TA
NOTE 4: Unused inputs must be held high or low to prevent them from floating.
Input transition rise or fall rate
0
10
ns/V
°
C
Operating free-air temperature
–40
85
P