- 9 -
Preliminary Datasheet
SPLC-35-FE-BX
CSFP Compact SFP Bi-Directional Transceiver
DS-6319
Rev 0.1
2010-11-01
4
Rate Select State
Rate select is not implemented.
3
Soft Rate Select
2
Tx Fault
Digital state of the TX Fault Output Pin. Updated within
100msec of change on pin.
1
LOS
Digital state of the LOS Output Pin. Updated within
100msec of change on pin.
0
Data_Ready_Bar
Indicates transceiver has achieved power up and data is
ready. Bit remains high until data is ready to be read at
which time the device sets the bit low.
111
All
Reserved
112
7
Temp High Alarm
Set when internal temperature exceeds high alarm level.
6
Temp Low Alarm
Set when internal temperature is below low alarm level.
5
Vcc High Alarm
Set when internal supply voltage exceeds high alarm level.
4
Vcc Low Alarm
Set when internal supply voltage is below low alarm level.
3
Tx Bias High Alarm
Set when internal supply voltage exceeds high alarm level.
2
Tx Bias Low Alarm
Set when internal supply voltage is below low alarm level.
1
Rx Power High Alarm
Set when TX output power exceeds high alarm level.
0
Rx Power Low Alarm
Set when TX output power is below low alarm level.
113
7
Vcc High Alarm
Set when Received Power exceeds high alarm level.
6
Vcc Low Alarm
Set when Received Power is below low alarm level.
5-0
Reserved
114
All
Reserved
115
All
Reserved
116
7
Temp High Warning
Set when internal temperature exceeds high Warning level.
6
Temp Low Warning
Set when internal temperature is below low Warning level.
5
Vcc High Warning
Set when internal supply voltage exceeds high Warning
level.
4
Vcc Low Warning
Set when internal supply voltage is below low Warning
level.
3
Tx Bias High Warning
Set when internal supply voltage exceeds high Warning
level.
2
Tx Bias Low Warning
Set when internal supply voltage is below low Warning
level.
1
Rx Power High Warning
Set when TX output power exceeds high Warning level.
0
Rx Power Low Warning
Set when TX output power is below low Warning level.
117
7
Vcc High Warning
Set when Received Power exceeds high Warning level.
6
Vcc Low Warning
Set when Received Power is below low Warning level.