56
49 Range Road
Windham, NH 03087
(603) 893-2330
FAX (603) 893-6280
TA Series Ordering Information
Dimensions and Connections
Input Voltage
Output
Model
Range
Voltage
Current
Number
9-36 Vdc
5 Vdc
5000mA
TA11-500-18
20-72 Vdc
5 Vdc
5000mA
TA11-500-48
9-36 Vdc
12 Vdc
2000mA
TA12-200-18
20-72 Vdc
12 Vdc
2000mA
TA12-200-48
9-36 Vdc
15 Vdc
1600mA
TA13-160-18
20-72 Vdc
15 Vdc
1600mA
TA13-160-48
9-36 Vdc
±12 Vdc
±1000mA
TA22-200-18
20-72 Vdc
±12 Vdc
±1000mA
TA22-200-48
9-36 Vdc
±15 Vdc
±800mA
TA23-160-18
20-72 Vdc
±15 Vdc
±800mA
TA23-160-48
9-36 Vdc
+5 / ±12Vdc
3500 / ±750mA
TA34-500-18
20-72 Vdc
+5 / ±12Vdc
3500 / ±750mA
TA34-500-48
9-36 Vdc
+5 / ±15Vdc
3500 / ±500mA
TA35-450-18
20-72 Vdc
+5 / ±15Vdc
3500 / ±500mA
TA35-450-48
Pins 0.040 (1.0) dia x 0.20 (5.1) lg min.
External OutputTrimming: Output may be externally
trimmed ±10% (Single output only).
Remote ON/Off Control (pin 8) common referenced
to Minus iput (pin 2).
On greater than 4 Vdc or open circuit
Off less than 1.2 Vdc
PIN CONNECTIONS
Single Output
1. +Input
2. -Input
3. No Pin
4. Trim
5. No Pin
6. +Output
7. Common
8. Remote On/Off
NOTES:
1. Ripple measured with a 3.3 mf tantalum capacitor
across each output.
2. Load regulation from full load to minimum load
with all other outputs at rated load.
3. Minimum current required on 5V out only.
4. Maximum total power from all outputs is 25 Watts
and no output is to exceed its maximum rated
current.
PIN CONNECTIONS
Multiple Outputs
1. +Input
2. -Input
3. +12 or 15 Output
4. Common
5. -12 or 15 Output
6. +5 Output
7. Common
8. Remote On/Off
11/01/2001