Housing
18 gauge steel housing with a tan epoxy powder coat
finish.
Knockouts provided for mounting up to three lamp
heads.
The suggested lamp head is the “D” Series round
sealed beam Par 36 tungsten. To order lamp heads
other than the suggested “D” head, refer to Chloride
Accessories Section..
Self-Diagnostics
The ACCU-TEST Self-Diagnostics option conducts
automatic and manual tests, and indicates real time
status of the lamp, battery and charger via LED indica-
tor lamps. Automatic tests include: Systems analysis
every 10 seconds, with actual load tests performed for
a 3 minute duration every 30 days. A manual tests is
available from 1 to 90 minutes.
Battery
Low maintenance, free electrolyte, wet cell, lead calci-
um battery.
Standard sustained emergency operation is for 90
minutes with the illumination source providing full
light output.
The suggested operating temperature range for lead
calcium batteries is 65°F
(19°C)
to 85°F
(30°C)
and
should provide a service life of 5 years.
Performance
Input power requirements
120 VAC - 0.66 amps, 80 watts
277 VAC - 0.30 amps, 80 watts
Code Compliance
The CCL/TCL Series meets or exceeds all performance
standards as required by UL 924, NFPA 70, NFPA 101,
NEC and OSHA.
Specification Data for CCL/TCL Series Steel Emergency Lighting Units
Suggested Specification
Furnish and install Chloride Systems emergency lighting unit model ________. The unit shall be constructed to meet Underwriter’s Laboratories, Inc. Standard #924
and the National Electrical Code (NEC).
INSTALLATION AND OPERATION -
Unit shall be easily field connected to a 120 or 277 VAC, 60 hertz, unswitched power source. Installation must comply with the
NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically transfer to battery power and maintain the required illumina-
tion level for a minimum period of 90 minutes. Upon restoration of utility power, the charger shall restore the battery to full charge within UL 924 requirements follow-
ing a rated discharge of not more than 90 minutes.
CHARGER -
Product shall utilize a fully automatic, voltage regulated, two-rate current limited solid-state charger. The charging system shall maintain the battery at
full capacity without the need for periodic exercising or equalization. The following features shall be standard: Low voltage disconnect (LVD), brownout protection and
AC lockout.
BATTERY -
The battery shall be a low maintenance, free electrolyte, wet cell, lead calcium battery. The lead calcium battery shall provide trouble-free operation in
temperatures up to 85°F (30°C).
HOUSING -
The unit housing shall be constructed of 18 gauge steel with a tan epoxy powder coat finish.
Chloride Systems
ISO 9001
A2528
C1063
R4
9/02 IH
272 West Stag Park Service Road
Burgaw NC 28425
Telephone: (910) 259 1000
Facsimile: (800) 258 8803
www.chloridesys.com
Lamp Head Photometrics
(For DL, suggested head for CCL)
Horizontal
Left 30
(For DK, suggested head for TCL)
Operation
DC
Suggested
Lamp Head
Watts to 87
1
of Rated Voltage*
2 hrs. 4 hrs. 8 hrs.
56
28.5
75
112.5
169
85.5
112.5
150
225
337.5
Voltage
Unit
1
1
2
hrs.
75
100
150
225
150
200
300
450
6
CCL75
CCL100
CCL150
CCL225
TCL150
TCL200
TCL300
TCL450
DL
DL
DL
DL
DK
DK
DK
DK
15
20
30
45
30
34
60
90
38
57
12
57
96
114
171
Electronics
120/277 VAC dual voltage input with surge-protect-
ed, solid-state charging circuitry provides for a
reliable charging system. The charging system is
furnished with low voltage disconnect, AC lockout,
brownout protection, AC indicator lamp and test
switch.
The low voltage disconnect (LVD) feature will dis-
connect the battery prior to an unacceptable deep
discharge, but not before the required 90 minute
emergency operation.
The AC lockout feature prevents battery drain prior to
the initial energizing of utility power, and allows the
installer to complete all wiring and electrical connec-
tions without energizing the emergency circuit.
The brownout protection circuitry will automatically
switch the unit into the emergency mode if the utility
voltage sags below 20% of nominal.
Battery charging circuitry is entirely solid-state, and
utilizes a fully automatic, voltage regulated charger.
Battery recharge time after full discharge is less than
the required UL 924 standard.
Line sensitive electronics cause an instantaneous
transfer to battery power if utility power is lost, or a
brownout condition is detected. When line voltage is
present and stabilized, the transfer circuitry switches
back to normal operation and begins recharging the
battery. The transfer circuitry can be tested via a
momentary test switch located on the housing.
Vertical
20
30
50
10
0
Up 20
10
feet 0
10
Down 20
.2
.1
40
60
70
.3
1
.5
Horizontal
20
30
50
10
0
Left 20
10
feet 0
10
Right 20
.2
.1
40
60
70
.3
1
.5
20
30
50
10
0
Up 20
10
feet 0
10
Down 20
Photometric No. 3
40
60
70
80
1
.3
.2
.1
.5
20
30
50
10
0
10
feet 0
10
20
Right 30
1
.3
.2
.1
20
.5
40
60
70
80
相关PDF资料
PDF描述
TCL450DY3-ACP2 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-AD 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-ADAL 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-ADTD 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-DCP 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
相关代理商/技术参数
参数描述
TCL450DY3-ACP2 制造商:未知厂家 制造商全称:未知厂家 功能描述:6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-AD 制造商:未知厂家 制造商全称:未知厂家 功能描述:6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-ADAL 制造商:未知厂家 制造商全称:未知厂家 功能描述:6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-ADTD 制造商:未知厂家 制造商全称:未知厂家 功能描述:6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery
TCL450DY3-DCP 制造商:未知厂家 制造商全称:未知厂家 功能描述:6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery