2 MAX SWAY (TYP)
DO NOT
SCALE FROM
THIS PRINT
W
TFM-1XX-XX-X-S-XX
No OF POSITIONS
ALL POSITIONS AVAILABLE
-03 THRU -50
-S: SINGLE ROW
(USE TFM-XX-S-XX-XX)
LEAD STYLE
PLATING SPECIFICATIONS
-S: SELECTIVE (USE T-1R16-XX-S-XX)
-F: FLASHED GOLD (USE T-1R16-XX-F-XX)
-P: GOLD FLASHED PALLADIUM NICKEL
(USE T-1R16-XX-P-XX)
-L: LIGHT GOLD (USE T-1R16-XX-L-XX)
OPTION
-A: ALIGNMENT PIN (USE TFM-XX-S-01-A)
(NOT AVAILABLE WITH -WT OPTION)
(SEE FIG. 5 SHEET 2)
-LC: LOCKING CLIP (USE LC-05-TM)
(NOT AVAILABLE WITH -WT OPTION)
(SEE FIG. 7 SHEET 3) (SEE NOTE 6)
-P: PICK AND PLACE PAD (USE PPP-15)
(SEE FIG. 6 SHEET 2)
(NOT AVAILABLE -03, -04 & -05 POSITIONS)
-K: POLYIMIDE FILM (SEE FIG. 3 SHEET 2)
(USE K-500-300)
-WT: WELD TABS (USE WT-25-07-T)
(SEE FIG. 4 SHEET 2)
(AVAILABLE ON -05 THRU -30 POS ONLY)
(NOT AVAILABLE WITH
-A OR -LC OPTIONS)
-TR: TAPE & REEL
(SEE SHEET 3, TAPE AND REEL VIEW)
-SN: SOLDER NAIL (USE WT-27-03)
(NOT AVAILABLE WITH -A, -LC, OR
-WT OPTIONS) (SEE FIG. 8 SHEET 3)
BODY SPECIFICATION
-01: T-1R16-01-X-2
THROUGH HOLE
-02: T-1R16-01-X-2
SURFACE MOUNT
-03: T-1R16-10-X
THROUGH HOLE
.100
REF
2.54
+ .025[.64])REF
((No. OF POSITIONS x .050[1.27])
+ .125[3.18])REF
((No. OF POSITIONS x .050[1.27])
.065 1.65
.083 2.11
.105
REF
2.67
.175
REF
4.45
.050
REF
1.27
C
01
"A"
"B" REF
.018 0.46
.014
REF
0.36
- .050[1.27])
((No. OF POSITIONS x .050[1.27])
2 MAX SWAY
(TYP)
"A"
FIGURE 1
(TFM-115-01-X-S-XX SHOWN)
.010
REF
0.25
.1635
REF
4.153
.2200 5.588
2 MAX TOE
(TYP)
2 MAX TOE (TYP)
SECTION "A"-"A"
"C"
IN-PROCESS
C
* NOT RELEASED FOR PRODUCTION
** NOT TOOLED
C
*
**
TABLE 1
ALLOWABLE COPLANARITY
POSITIONS
-03 THRU -29
.004 MAX
-030 THRU -39
.006 MAX
-40 THRU -50
.008 MAX
TABLE 2
LEAD STYLE
BODY
"A"
"B"
"C"
-01
TFM-XX-S-XX-XX
0.075 [1.91]
0.133 [3.38] 0.4285 [10.884]
-02
TFM-XX-S-XX-XX
N/A
0.133 [3.38] 0.4285 [10.884]
-03
TFM-XX-S-XX-XX
0.109 [2.77]
0.140 [3.56]
0.644 [16.36]
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
MATERIAL:
.050 C.L. SINGLE ROW SHROUDED TERMINAL STRIP
BY:
TFM-1XX-XX-X-S-XX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
D. SCHMELZ 8/21/2008
3
1
SHEET SCALE: 1:0.4
INSULATOR: LIQUID CRYSTAL POLYMER, COLOR: BLACK
TERMINAL: PHOSPHOR BRONZE
F:\DWG\MISC\MKTG\TFM-1XX-XX-X-S-XX-MKT.SLDDRW
NOTES:
1.
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PUSHOUT FORCE TO BE 16 OZ FOR TERMINALS, 12 OZ FOR WELD TABS,
AND 8 OZ FOR LOCKING CLIPS.
3. MEASURED FROM BEND.
4. .003[.08] MAXIMUM TERMINAL BURR.
5. .005 MAXIMUM HEIGHT VARIATION BETWEEN ANY TWO PINS.
6.
DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, THE -LC OPTION
IS NOT COMPATIBLE WITH AUTO PLACEMENT. SAMTEC RECOMMENDS
MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH THE -LC OPTION.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
REVISION W