Filename: tfs 869g.doc
Version 1.2
05.01.2006
VI TELEFILTER
Filter specification
TFS 869G
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
50
Output:
50
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 869,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
Insertion loss
ae
2,8
dB
max.
4,5
dB
Nominal frequency
fN
-
869,0
MHz
Passband
PB
-
fN
±
1,0
MHz
Pass band ripple
0,6
dB
max.
0,8
dB
Absolute attenuation
aabs
0,3
MHz
…
856,4
MHZ
44
dB
min.
40
dB
856,4
MHz
…
858,5
MHZ
32
dB
min.
20
dB
879,0
MHz
…
883,0
MHZ
22
dB
min.
20
dB
883,0
MHz
… 1200,0
MHZ
48
dB
min.
45
dB
1200,0
MHz
… 2000,0
MHZ
37
dB
min.
35
dB
VSWR within PB
**
1,3 : 1
max.
2,0 : 1
Input power level
-
max.
25
dBm
Operating temperature range
OTR
-
- 40 °C ... + 85 °C
Storage temperature range
-
- 40 °C ... + 90 °C
Temperature coefficient of frequency
TCf *
- 32
ppm/K
-
*)
f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz)
**) at ambient temperature
Generated:
Checked / Approved: